24
HAMEG Instruments GmbH • Industriestr. 6 • D-63533 Mainhausen • Deutschland
Subject to change without notice
Tel.: +49 (0) 6182 800 0 • Fax: +49 (0) 6182 800 100 • E-Mail: [email protected]
Geschäftsführer: Dipl.-Ing. Holger Asmussen, Dipl.-Ing. Andre Vander Stichelen • AG Offenbach am Main HRB 41200
1
1
HAMEG Instruments GmbH • Industriestraße 6 • D-63533 Mainhausen
Subject to change without notice
Tel.: +49 (0) 6182 800 0 • Fax: +49 (0) 6182 800 100 • E-Mail: [email protected]
Geschäftsführer: Dipl.-Ing. Holger Asmussen • AG Offenbach am Main HRB 41200
Firmware Version: 01.020 and later
English
S C P I P r o g r a m m e r s M a n u a l
H M S S e r i e s
1
HAMEG Instruments GmbH • Industriestraße 6 • D-63533 Mainhausen
Subject to change without notice
Tel.: +49 (0) 6182 800 0 • Fax: +49 (0) 6182 800 100 • E-Mail: [email protected]
Geschäftsführer: Dipl.-Ing. Holger Asmussen • AG Offenbach am Main HRB 41200
Firmware Version: 01.020 and later
English
S C P I P r o g r a m m e r s M a n u a l
H M S S e r i e s
HMO352x, HMO2524
HMO72x ... HMO202x
Firmware Version: 03.00 and later
English
:ACQuire
:CHAN1OFFSet
:DISPlay
:HCOPy
*ESR?
*OPC?
:LOGic:SIZE
:MEASure
:POD1
:SYSTem
*SRE?
S C P I P r o g r a m m e r s M a n u a l
H M O S e r i e s
SCPI Commands HMC8012
SYSTem:BEEPer:STATe
<
State
>
Switches the front panel control beeper on or off. For example, if the control beeper is disabled, you don‘t get a control
beep during the manual or signgle trigger.
Parameters:
<State>
ON | OFF
*RST:
ON
SYSTem:BEEPer:STATe?
Returns the state of the front panel control beeper. Returns “0” for deactivated (OFF) and “1” for activated (ON)
control beeper.
*RST:
1
SYSTem:BEEPer[:IMMediate]
The instrument returns a single beep immediately.
Usage:
Setting only
SYSTem:ERRor[:NEXT]?
Queries an error and removes it from the queue. Positive error numbers are instrument-dependent. Negative error
numbers are
reserved by the SCPI standard. If the queue is empty, the response is 0, “No error“.
Usage:
Query only
SYSTem:LOCal
Sets the system to front panel control. The front panel control is unlocked.
Usage:
Setting only
SYSTem:REMote
Sets the system to remote state. The front panel control is locked and can be unlock via soft menu key „Unlock keys“
(front panel) or SCPI command SYSTem:LOCal.
Usage:
Setting only
SYSTem:RWLock
Sets the system to remote state. The front panel control is locked and can not be unlocked via soft menu key „Unlock
keys“ (front panel). You are only able to unlock the front panel control via SCPI command SYSTem:LOCal.
Usage:
Setting only
SYSTem:VERSion?
Returns the version of the SCPI (= Standard Commands for Programmable Instruments) standard.
Usage: