General purpose output (GPO) settings
information
External devices can be controlled by the neutral
general purpose output (GPO). By default the function
is low.
OR
AUX output will change status if function OR any of
the related inputs are active.
AND << Please don’t use>>
AUX output will change status, if the function and all
related inputs are active.
24 V
Standard output: Function AND / OR logic HIGH ->
24 V to solenoid, otherwise 0 V.
0 V
Inverted output: Function AND / OR logic HIGH-> 0
V to solenoid, otherwise 24 V.
*The output level can be adjusted independently of
input use!
*Possible inputs: Super AUX A / B / C custom, general
purpose input (GPI) AUX 4 / 5
Traction assist (TA+) settings information
Function can be controlled / extended by several inputs.
OR
AUX output will change status if function OR any of
the related inputs are active.
AND
AUX output will change status, if the function AND all
related inputs are active.
24 V
Standard output: Function AND / OR logic HIGH ->
24 V to solenoid, otherwise 0 V.
0 V
Inverted output: Function AND / OR logic HIGH-> 0
V to solenoid, otherwise 24 V.
*The output level can be adjusted independently of
input use!
*Possible inputs: Super AUX A / B / C custom, general
purpose input (GPI) AUX 4 / 5