APPENDIX A – UNDERSTANDING HLC 

A3 

HOUSE CONTROLLER

(CONTROLS UP TO 8 ROOMS)

UNIT 25

ROOM 4

UNIT 9

ROOM 2

UNIT 1

ROOM 1

UNIT 17

ROOM 3

UNIT 57

ROOM 8

UNIT 41

ROOM 6

UNIT 33

ROOM 5

UNIT 49

ROOM 7

AVAILABLE UNITS:

8, 16, 24, 32, 40, 48, 56, and 64

 
The Lumina controller keeps track of the exact status of each unit even when a lighting scene is initiated by the Room Controller.  
Room Controllers also keep track of when individual switches in a room are turned on and off.  When all of the lighting loads in a 
room are turned off, the “Off” indicator is illuminated.  If any of the lighting loads in a room are turned on at an HAI UPB™ Wall 
Switch or Dimmer, the “On” indicator will illuminate and the “Off” indicator is turned off.  Likewise, if the “On” indicator or one of 
the scene indicators is illuminated, and then all of the lighting loads are turned off at HAI UPB™ Wall Switches, the “Off” indicator 
will illuminate and any others are turned off.   
 

About House Controllers 

 

Each HAI UPB™ 8-Button House Controller allows for controlling all 8 rooms 
of lighting where HAI UPB™ Wall Switches, Dimmers, and Modules have been 
installed.   
 
Each button on the House Controller is used to toggle all of the lights in the 
respective room on and off.  When the room is turned on, the LED indicator 
behind the respective button is illuminated and all of the lights in the room are 
turned on.  When the room is turned off, the LED indicator behind the respective 
button is turned off and all of the lights in the room are turned off.  If a lighting 
load in the respective room is turned on, the LED indicator behind the button is 
illuminated.  When all lighting loads in the respective room are turned off, the 
LED indicator behind the button is turned off.   
 
Each House Controller controls 8 consecutive rooms (i.e. Room 1-8, Room 9-16, 
Room 17-24, and Room 25-31). To configure a House Controller to control a 
group of 8 rooms, it must be set to the last unit number in one of the respective 
rooms.  For example, a House Controller set to Unit 8, 16, 24, 32, 40, 48, 56, or 
64 can be used to control Rooms 1-8.  This allows you to have up to 8 House 
Controllers throughout the house that control Rooms 1-8.   
 
 
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
When used with Lumina Pro, House Controllers for Rooms 9-16, 17-24, and 25-31 are configured in a similar manner.  For example: 
 

 

Unit 72, 80, 88, 96, 104, 112, 120, and 128 can be used to control Rooms 9-16. 

 

Unit 136, 144, 152, 160, 168, 176, 784, and 192 can be used to control Rooms 17-24. 

 

Unit 200, 208, 216, 224, 232, 240, and 248 can be used to control Rooms 25-31. 

UNIT 1

ROOM 1

ROOM 1

UNIT 5

ROOM 1

UNIT 6

ROOM 1

ROOM 7

ROOM 1

UNIT 2

ROOM 1

UNIT 3

ROOM 1

UNIT 4

LIVING ROOM

ROOM CONTROLLER

LIGHTING LOADS IN

LIVING ROOM

UNIT 8

Summary of Contents for lumina

Page 1: ...HOME AUTOMATION INC Lumina and Lumina Pro Lighting and Automation System Quick Start Installation Guide Document Number 44I00 1 Rev 2 12 February 2006...

Page 2: ...g instructions please download the following document s from the HAI web site 44R00 1 Lumina Advanced Application Guide 44R00 2 Lumina Pro Advanced Application Guide www homeauto com Copyright 2006 Ho...

Page 3: ...NE ZONE INPUT INPUT ONLY ZONES 9 16 MAY BE CONFIGURED AS ENERGY SAVER ZONES ONLY ZONE 16 MAY BE USED FOR HAI REMOTE CONTROL THERMOSTATS OUTPUT OUTPUT 1 Amp Max 11A02 2 6 KEYPAD CABLE Supplied OUTPUT B...

Page 4: ...ROUND THE LUMINA CONTROLLER S EARTH GND TERMINAL TO A COLD WATER PIPE OR TO A 4 FOOT GROUND ROD TO PRESERVE ITS BUILT IN TRANSIENT PROTECTION USE 14 GAUGE WIRE TRANSIENT PROTECTION WILL NOT WORK IF TH...

Page 5: ...ith a screwdriver c Mount the back plate to the wall Mounting holes are designed to fit on a single or double gang box or directly to the wall d Plug the cable into the connector on the keypad Printed...

Page 6: ...ed POWER TRANSFORMER 8 Connect the Battery Unplug the Power Transformer to shut down the controller Connect the black battery wire to the negative battery terminal of the supplied battery Connect the...

Page 7: ...nu before selecting a function if the number for the desired menu item is known Error Beeps If you press a key that is invalid for the function that you are doing the keypad will beep 3 times indicati...

Page 8: ...ime is not currently being observed between fall and spring or is not observed in your geographic location set this item to No This item is used to correctly calculate the times for sunrise and sunset...

Page 9: ...Load names Use the up arrow and down arrow keys to scroll through the list of available names for the device When appropriate name appears press the key to select that name for the device The name no...

Page 10: ...nfigure each device as follows STEP 1 On the Lumina keypad from the top level display press 6 STATUS and then press 1 CTRL The first named unit is displayed Living Room STATUS OFF STEP 2 Configuring R...

Page 11: ...it in Setup mode as follows Lighting Load Setup Step Operation 1 Tap the rocker switch quickly 5 times 2 The HAI UPB Wall Dimmer or Switch will flash the lighting load one time and blink its LED blue...

Page 12: ...s CONFIGURE UNIT 2 COMPLETED Once completed press the key to return to the Status display Repeat Step 5 for each unnamed Room Controller STEP 6 Configure Unnamed House Controllers House Controllers th...

Page 13: ...D and one On Scene preset lighting levels for each device when the room is turned on To set a lighting scene using a Room Controller Each lighting scene can also be set or easily changed using the pus...

Page 14: ...sired lighting levels may be set manually at the switch by pressing the top of the paddle to brighten the light or the bottom of the paddle to dim the light 2 After the desired lighting levels are set...

Page 15: ...E CONTROLLER UNIT 48 HLC LOAD OR HOUSE CONTROLLER UNIT 56 HLC LOAD OR HOUSE CONTROLLER UNIT 64 UNIT 1 ROOM 2 UNIT 9 ROOM 3 UNIT 17 ROOM 4 UNIT 25 ROOM 5 UNIT 33 ROOM 6 UNIT 41 ROOM 7 UNIT 49 ROOM 8 UN...

Page 16: ...are used the first Room Controller should be set to the first unit number in the group i e Unit 1 Room 1 additional Room Controllers can be used by setting each to any other unused unit number in the...

Page 17: ...m is turned on the LED indicator behind the respective button is illuminated and all of the lights in the room are turned on When the room is turned off the LED indicator behind the respective button...

Page 18: ...er which controls up to 8 Rooms ROOM 1 Living Room Unit Unit Number HLC Device Type Name 1st Unit 1 Room Controller Living Room 2nd Unit 2 Lighting Load Room Controller 3rd Unit 3 Lighting Load Room C...

Page 19: ...16 Lighting Load House Controller ROOM 3 Unit Unit Number HLC Device Type Name 1st Unit 17 Room Controller 2nd Unit 18 Lighting Load Room Controller 3rd Unit 19 Lighting Load Room Controller 4th Unit...

Page 20: ...m Controller 4th Unit 52 Lighting Load Room Controller 5th Unit 53 Lighting Load Room Controller 6th Unit 54 Lighting Load Room Controller 7th Unit 55 Lighting Load Room Controller 8th Unit 56 Lightin...

Page 21: ...se Controller ROOM 12 Unit Unit Number HLC Device Type Name 1st Unit 89 Room Controller 2nd Unit 90 Lighting Load Room Controller 3rd Unit 91 Lighting Load Room Controller 4th Unit 92 Lighting Load Ro...

Page 22: ...ghting Load Room Controller 5th Unit 125 Lighting Load Room Controller 6th Unit 126 Lighting Load Room Controller 7th Unit 127 Lighting Load Room Controller 8th Unit 128 Lighting Load House Controller...

Page 23: ...nit Unit Number HLC Device Type Name 1st Unit 161 Room Controller 2nd Unit 162 Lighting Load Room Controller 3rd Unit 163 Lighting Load Room Controller 4th Unit 164 Lighting Load Room Controller 5th U...

Page 24: ...Lighting Load Room Controller 6th Unit 198 Lighting Load Room Controller 7th Unit 199 Lighting Load Room Controller 8th Unit 200 Lighting Load House Controller ROOM 26 Unit Unit Number HLC Device Type...

Page 25: ...troller 7th Unit 231 Lighting Load Room Controller 8th Unit 232 Lighting Load House Controller ROOM 30 Unit Unit Number HLC Device Type Name 1st Unit 233 Room Controller 2nd Unit 234 Lighting Load Roo...

Reviews: