APPENDIX A – UNDERSTANDING HLC 

A2 

 
HLC OVERVIEW 

 
HAI Lighting Control (HLC) combines HAI UPB™ Wall Switches, Dimmers, and Modules, HAI UPB™ Room Controllers, and HAI 
UPB™ House Controllers to create lighting scenes that set the proper mood and ambiance for various activities throughout a home.   
 
HLC format is a defined structure for configuring, programming, and operating all the HLC lighting devices in a home.   
 
Room Controllers control up to 7 lighting loads in a room.  House Controllers control up to 8 Rooms of HLC lighting. 
 
HAI manufactured UPB™ devices (collectively referred to as HLC devices) are configured using the Lumina keypad.   
 

About Rooms 

 

Each “room” of HLC lighting consists of 8 consecutive unit numbers, starting at Unit 1 (i.e. Room 1 = Units 1-8, Room 2 = Units 9-
16, Room 3 = Units 17-24, etc.).  Each room can consist of a maximum of 8 HLC devices, configured as follows: 
 

 

Up to 7 HAI UPB™ Wall Switches, Dimmers, and/or Modules (for controlling up to 7 lighting loads in a room or area)  

 

1 or more Room Controllers (set a scene in a room, turn the room on and off, and dim and brighten the room) 

 

1 House Controller (for controlling up to 8 rooms of HLC lighting) 

 
The first unit number in each room (i.e. 1, 9, 17, 25, etc.) is reserved for controlling the room; this is where the Room Controller will 
reside.  The name for this unit should reflect the room name (e.g. Living Room, Kitchen, Great Room, Theater, etc.).  HLC Wall 
Switches, Dimmers, or Modules cannot be programmed to these unit numbers.  If one or more Room Controllers are used, the first 
Room Controller should be set to the first unit number in the group (i.e. Unit 1 – Room 1); additional Room Controllers can be used 
by setting each to any other unused unit number in the group between the 2

nd

 and 7

th

 unit number (i.e. Unit 2-7 – Room 1). 

 

UNIT 1

ROOM 1

ROOM 1

UNIT 6

ROOM 1

UNIT 7

ROOM 1

ROOM 8

ROOM 1

UNIT 2

ROOM 1

UNIT 3

ROOM 1

UNIT 4

ROOM 1

UNIT 5

LIVING ROOM

ROOM CONTROLLER

LIGHTING LOADS IN

LIVING ROOM

         

UNIT 1

ROOM 1

ROOM 1

UNIT 6

ROOM 1

UNIT 7

ROOM 1

ROOM 8

ROOM 1

UNIT 3

ROOM 1

UNIT 4

ROOM 1

UNIT 5

1ST LIVING ROOM

ROOM CONTROLLER

LIGHTING LOADS IN

LIVING ROOM

UNIT 2

ROOM CONTROLLER

2ND LIVING ROOM

ROOM 1

 

 
 

About Room Controllers 

 
The HAI UPB™ 6-Button Room Controller allows for lighting control of a room where HAI UPB™ Wall Switches, Dimmers, and 
Modules have been installed. From a Room Controller the room can be turned off (all loads in the group are turned off), turned on (all 
loads in the group are turned on), brightened (all loads are brightened from their current level), dimmed (all loads are dimmed from 
their current level), or set to one of 4 lighting scenes (A-D).   
 

Room Controller LED Indicators 

 
When the room is turned on, the LED indicator behind the “On” button is illuminated and all others are turned off.  When the room is 
turned off, the LED indicator behind the “Off” button is illuminated and all others are turned off.  When the room is brightened, the 
LED indicator behind the “On” is illuminated and all others are turned off.  When the room is dimmed, the LED indicator that is 
currently illuminated stays on.  When the room is set to a lighting scene (A-D), the LED indicator behind the respective scene letter is 
illuminated and all others are turned off.  

Summary of Contents for lumina

Page 1: ...HOME AUTOMATION INC Lumina and Lumina Pro Lighting and Automation System Quick Start Installation Guide Document Number 44I00 1 Rev 2 12 February 2006...

Page 2: ...g instructions please download the following document s from the HAI web site 44R00 1 Lumina Advanced Application Guide 44R00 2 Lumina Pro Advanced Application Guide www homeauto com Copyright 2006 Ho...

Page 3: ...NE ZONE INPUT INPUT ONLY ZONES 9 16 MAY BE CONFIGURED AS ENERGY SAVER ZONES ONLY ZONE 16 MAY BE USED FOR HAI REMOTE CONTROL THERMOSTATS OUTPUT OUTPUT 1 Amp Max 11A02 2 6 KEYPAD CABLE Supplied OUTPUT B...

Page 4: ...ROUND THE LUMINA CONTROLLER S EARTH GND TERMINAL TO A COLD WATER PIPE OR TO A 4 FOOT GROUND ROD TO PRESERVE ITS BUILT IN TRANSIENT PROTECTION USE 14 GAUGE WIRE TRANSIENT PROTECTION WILL NOT WORK IF TH...

Page 5: ...ith a screwdriver c Mount the back plate to the wall Mounting holes are designed to fit on a single or double gang box or directly to the wall d Plug the cable into the connector on the keypad Printed...

Page 6: ...ed POWER TRANSFORMER 8 Connect the Battery Unplug the Power Transformer to shut down the controller Connect the black battery wire to the negative battery terminal of the supplied battery Connect the...

Page 7: ...nu before selecting a function if the number for the desired menu item is known Error Beeps If you press a key that is invalid for the function that you are doing the keypad will beep 3 times indicati...

Page 8: ...ime is not currently being observed between fall and spring or is not observed in your geographic location set this item to No This item is used to correctly calculate the times for sunrise and sunset...

Page 9: ...Load names Use the up arrow and down arrow keys to scroll through the list of available names for the device When appropriate name appears press the key to select that name for the device The name no...

Page 10: ...nfigure each device as follows STEP 1 On the Lumina keypad from the top level display press 6 STATUS and then press 1 CTRL The first named unit is displayed Living Room STATUS OFF STEP 2 Configuring R...

Page 11: ...it in Setup mode as follows Lighting Load Setup Step Operation 1 Tap the rocker switch quickly 5 times 2 The HAI UPB Wall Dimmer or Switch will flash the lighting load one time and blink its LED blue...

Page 12: ...s CONFIGURE UNIT 2 COMPLETED Once completed press the key to return to the Status display Repeat Step 5 for each unnamed Room Controller STEP 6 Configure Unnamed House Controllers House Controllers th...

Page 13: ...D and one On Scene preset lighting levels for each device when the room is turned on To set a lighting scene using a Room Controller Each lighting scene can also be set or easily changed using the pus...

Page 14: ...sired lighting levels may be set manually at the switch by pressing the top of the paddle to brighten the light or the bottom of the paddle to dim the light 2 After the desired lighting levels are set...

Page 15: ...E CONTROLLER UNIT 48 HLC LOAD OR HOUSE CONTROLLER UNIT 56 HLC LOAD OR HOUSE CONTROLLER UNIT 64 UNIT 1 ROOM 2 UNIT 9 ROOM 3 UNIT 17 ROOM 4 UNIT 25 ROOM 5 UNIT 33 ROOM 6 UNIT 41 ROOM 7 UNIT 49 ROOM 8 UN...

Page 16: ...are used the first Room Controller should be set to the first unit number in the group i e Unit 1 Room 1 additional Room Controllers can be used by setting each to any other unused unit number in the...

Page 17: ...m is turned on the LED indicator behind the respective button is illuminated and all of the lights in the room are turned on When the room is turned off the LED indicator behind the respective button...

Page 18: ...er which controls up to 8 Rooms ROOM 1 Living Room Unit Unit Number HLC Device Type Name 1st Unit 1 Room Controller Living Room 2nd Unit 2 Lighting Load Room Controller 3rd Unit 3 Lighting Load Room C...

Page 19: ...16 Lighting Load House Controller ROOM 3 Unit Unit Number HLC Device Type Name 1st Unit 17 Room Controller 2nd Unit 18 Lighting Load Room Controller 3rd Unit 19 Lighting Load Room Controller 4th Unit...

Page 20: ...m Controller 4th Unit 52 Lighting Load Room Controller 5th Unit 53 Lighting Load Room Controller 6th Unit 54 Lighting Load Room Controller 7th Unit 55 Lighting Load Room Controller 8th Unit 56 Lightin...

Page 21: ...se Controller ROOM 12 Unit Unit Number HLC Device Type Name 1st Unit 89 Room Controller 2nd Unit 90 Lighting Load Room Controller 3rd Unit 91 Lighting Load Room Controller 4th Unit 92 Lighting Load Ro...

Page 22: ...ghting Load Room Controller 5th Unit 125 Lighting Load Room Controller 6th Unit 126 Lighting Load Room Controller 7th Unit 127 Lighting Load Room Controller 8th Unit 128 Lighting Load House Controller...

Page 23: ...nit Unit Number HLC Device Type Name 1st Unit 161 Room Controller 2nd Unit 162 Lighting Load Room Controller 3rd Unit 163 Lighting Load Room Controller 4th Unit 164 Lighting Load Room Controller 5th U...

Page 24: ...Lighting Load Room Controller 6th Unit 198 Lighting Load Room Controller 7th Unit 199 Lighting Load Room Controller 8th Unit 200 Lighting Load House Controller ROOM 26 Unit Unit Number HLC Device Type...

Page 25: ...troller 7th Unit 231 Lighting Load Room Controller 8th Unit 232 Lighting Load House Controller ROOM 30 Unit Unit Number HLC Device Type Name 1st Unit 233 Room Controller 2nd Unit 234 Lighting Load Roo...

Reviews: