Page 30
Status of a Unit
To see the status of a unit, from the control menu, press the ' # ' key. The last command along with any time (hh:mm:ss)
remaining on a timed command will be displayed.
Entry Lights 1:22:10
STATUS
ON
At this point, one of the menu choices may be entered or the ' * ' or ' # ' key may be pressed to redisplay the menu.
Note: If an X-10 signal is received over the powerline, Lumina will automatically update the status of the X-10 unit.
Internal Flags
The easiest way to define a flag it to refer to it as a "virtual relay". A flag can be in one of three separate states: On, Off, or set to
a value between 0 and 255. If a flag has a value of 1-255, it is considered "On". If a flag has a value of 0 it is considered "Off".
Flags are a powerful programming tool that can be used in several ways to accomplish advanced programming routines. Any
Flag can also be used as a counter. Counters can be incremented, decremented, or set to a specific value (0 to 255).
When a counter is decremented to zero, the "When Unit Off" macro is executed. A counter will not decrement below zero. The
counter will, however, roll over from 255 to 0 when incremented. The "When Unit Off" macro will be executed when the counter
rolls over. This allows two counters to be cascaded to form a larger counter.
When the counter is incremented from 0 to 1, the "When Unit On" macro will now execute. This will allow you to execute a
command when the Flag is incremented (counting up) from zero.
The Set command is used to set the counter to a value from 0 to 255. No macros are executed when the counter is set to zero or
when the counter is changed from zero using the set command. This allows a counter to be reset without executing macros or
programs associated with the counter counting to zero. Turn the Flag On or Off to have the associated macro execute. When the
Flag is turned Off, its value is set to zero (0). When the Flag is turned On, its value is set to one (1). The counter is considered
On for program conditions if it is nonzero (1-255).
Flags can be turned Off, On, Decremented (DEC), Incremented (INC), Set, and Timed ON/OFF.
Controlling Outputs
The Lumina has eight outputs that can be used to switch relays. Outputs 1-8 are controlled as Unit Numbers 65-72, respectively.
The Lumina has 2 additional outputs labeled INT HORN and EXT HORN. Unit Number 73 is used to control INT HORN output
and Unit Number 74 is used to control the EXT HORN output.
These 12 VDC voltage outputs are connected directly to the Lumina and not through a module. If you have something connected
to these outputs, such as a sprinkler system, your installer will explain its operation.
Outputs cannot be brightened or dimmed and are
not
affected by All ON or All Off commands.