Page 85
TEMPERATURE ALARM AND EXTENDED RANGE TEMPERATURE ALARM
The TEMPERATURE alarm zone type will generate an alarm (keypad beeper) and will use the voice dialer to dial out if the
temperature goes above the high setpoint or drops below the low setpoint.
HUMIDITY
The HUMIDITY zone type is used to monitor indoor and outdoor humidity levels from 0 to 100 percent using the
Model 31A00-2 (31A00-8 Extended Range) Indoor/Outdoor Temperature and Humidity Sensor. It sets the zone secure/not ready
state for program conditionals and event button activated programs.
NOTE ON TEMPERATURE AND HUMIDITY ZONE TYPES
Outdoor temperature, temperature, and temperature alarm zone types all have Heat (Low) and Cool (High) setpoints. The zone is
"Not Ready" when the temperature is above the high setpoint or below the low setpoint. The zone is "Secure" when the
temperature is between the setpoints. Setting a setpoint to 0 disables the setpoint.
Except for a type 83 (Temp Alarm) and 87 (ER Temp Alarm), the alarm is not activated. The zone "Not Ready" or "Secure"
status is used to activate button programs and program conditionals.
Setup Temperatures
To configure temperature settings and thermostats from the Installer Setup Menu, press the 5 (Temp) key.
Temperature Display
This allows you to choose between Fahrenheit and Celsius temperature format.
TEMPERATURE DISPLAY: 1
1=FAHRENHEIT
2=CELSIUS
↓
Thermostat Type
If HAI thermostats are part of the system, this item specifies the thermostat type for each thermostat (this enables the thermostat).
When any Thermostat Type is changed from the default setting of "Not Used", Zone 16 and Output 8 is automatically configured
for thermostats. There is no need to change the Zone Type for Zone 16 or Output Type for Output 8.
For thermostat types, the current setting is shown on the bottom line.
THERMOSTAT 1 TYPE: 0
NOT USED #=CHNG
THROUGH
THERMOSTAT 4 TYPE: 0
NOT USED #=CHNG
↑
To enable or change a thermostat type, press the ' # ' key. Use the arrow keys to scroll through the list of thermostat types, then
press ' # ' to select a new type. The display shows:
SELECT TYPE: 1
AUTO HEAT/COOL
↓
TYPE NUMBER
DESCRIPTION
AUTO HEAT/COOL
1
Automatic changeover heat and cool thermostat
HEAT/COOL
2
Manual changeover heat and cool thermostat
HEAT
ONLY
3 Heating
only
thermostat
COOL
ONLY
4 Cooling
only
thermostat
SETPOINT
ONLY 5 Setpoint
only
thermostat