Page 8
HAI Thermostats
Lumina supports up to 4 HAI RC-Series Communicating Thermostats. The controller can send commands to the thermostat to
change mode, cool setting, heat setting, status of fan and hold, and other items.
Run a 3 (or 4) conductor wire from Lumina to the thermostat location. All thermostats are connected in parallel to Zone 16 and
Output 8. Connect the red COMM cable wire with the black COMM cable wire. Make the connections (
as shown below)
using
the supplied wire splices.
HAI Thermostats are preprogrammed with energy saving settings recommended under the EPA Energy Star program. When used
with a Lumina systems, HAI recommends that the thermostat be configured as "non-programmable" - (See Setup Item 03 -
"Display Options") in the thermostat’s installation manual.