Settings
1 9 0
96-8000 rev R June 2007
150 APC Pallet 4 Load X
151 APC Pallet 4 Load Y
152 APC Pallet 4 Unload X
153 APC Pallet 4 Unload Y
154 APC Pallet 3 & 4 Safe X
See Settings 121-129
155 Load Pocket Tables
This setting should only be used when a software upgrade is performed and/or memory has been cleared and/or the
control is re-initialized. In order to replace the contents of the side-mount tool changer pocket tool table with the data
from the file, the setting must be ON.
If this setting is OFF when loading an Offset file from a floppy disk or RS-232, the contents of the Pocket Tool table
will be unaltered. Setting 155 automatically defaults to OFF when the machine is turned on.
156 Save Offset with PROG
Turning this setting ON will have the control save the offsets in the same file as the programs, but under the heading
O999999. The offsets will appear in the file before the final % sign.
157 Offset Format Type
This setting controls the format in which offsets are saved with programs.
When it is set to A the format looks like what is displayed on the control, and contains decimal points and column
headings. Offsets saved in this format can be more easily edited on a PC and later reloaded into the control.
When it is set to B, each offset is saved on a separate line with an N value and a V value.
158,159,160 XYZ Screw Thermal COMP%
These settings can be set from -30 to +30 and will adjust the existing screw thermal compensation by -30% to
+30% accordingly.
162 Default to Float
When this setting is ON, the control will add a decimal point to values entered without a decimal point (for certain
address codes). When this setting is Off, the values following the address codes are treated as machinist’s notation
(i.e., thousandths or ten-thousandths.) For example:
Value entered With Setting OFF With Setting ON
In Inch mode
X-2 X-.0002 X-2.
In MM mode
X-2 X-.002 X-2.
This feature applies to the following address codes:
X,Y,Z,A,B,C,E,F,I,K,U,W
D (except with G73)
R (except with G71 in YASNAC mode)
Note that this setting affects the interpretation of all programs entered either manually or from disk or via RS-232. It
does not alter the effect of setting 77 Scale Integer F.
163 Disable .1 Jog Rate
This setting disables the highest jog rate. If the highest jog rate is selected, the next lower rate is automatically
selected instead.
164 Rotary Increment
This setting applies to the Rotary Index button on the EC300. It specifies the rotation for the rotary table in the load
station. It should be set to a value from -360 to 360 degrees. For example, entering “90” will rotate the pallet 90°
each time the rotary index button is pressed. If it is set to zero, the rotary table will not rotate.
Summary of Contents for Mill
Page 12: ...96 8000 rev R June 2007 Safety 5 ...
Page 14: ...96 8000 rev R June 2007 Safety 7 LATHE WARNING DECALS ...
Page 15: ...8 Safety 96 8000 rev R June 2007 ...
Page 17: ...10 Introduction 96 8000 rev R June 2007 ...
Page 117: ...110 4 5 Axis Programming 96 8000 rev R June 2007 ...
Page 199: ...Settings 192 96 8000 rev R June 2007 ...