Settings
96-8000 rev R June 2007
Q304 - Previous Cycle Time
Q400 - not currently used
Q401 - not currently used
Q402 - M30 Parts Counter #1 (resettable at control)
Q403 - M30 Parts Counter #2 (resettable at control)
Q500 - Three-in-one (PROGRAM, Oxxxxx, STATUS, PARTS, xxxxx)
Q600 Macro or system variable
The user has the ability to request the contents of any macro or system variable by using the Q600 command, for
example, “Q600 xxxx” where xxxx is the macro variable.
In addition, Macro variables #1-33, 100-199, 500-699, 800-999 and #2001 thru #2800 can be “written to” using an “E”
command, for example, “Exxxx yyyyyy.yyyyyy” where xxxx is the macro variable and yyyyyy.yyyyyy is the new
value. Note that this command should only be used when there are no alarms present.
Status Relays Special Additional Remote Machine Data Collection
This feature can be accomplished with the installation of the following optional parts: 8 Spare M-code relay board (all
8 become dedicated to below functions and can no longer be used for normal M-code operation), a power-on relay,
an extra set of Emergency Stop contacts, and a set of special cables; contact your dealer for pricing information on
these parts.
Once installed, output relays 40 thru 47, a power-on relay and the Emergency Stop switch are used to communicate
the status of the control. Note: Parameter 315 bit 26 “STATUS RELAYS” must be enabled. Standard spare M-codes
are still available for use.
The following communications will be received (* are only available when used with the optional parts):
* E-STOP contacts. This will be closed when the E-STOP button is pushed.
* Power ON - 115 VAC. Indicates that the control is turned ON. It should be wired to a 115 VAC coil relay for inter-
face.
* Spare Output Relay 40. Indicates that the control is In-Cycle (running.)
* Spare Output Relay 41 and 42:
11 = MEM mode & no alarms (AUTO mode.)
10 = MDI mode & no alarms (Manual mode.)
01 = Single Block mode (Single mode)
00 = other modes (zero, DNC, jog, list prog, etc.)
* Spare Output Relay 43 and 44:
11 = Feed Hold stop (Feed Hold.)
10 = M00 or M01 stop
01 = M02 or M30 stop (Program Stop)
00 = none of the above (could be single block stop or RESET.)
* Spare Output Relay 45 (Feed Rate Override is active and Feed Rate is NOT 100%)
* Spare Output Relay 46 (Spindle Speed Override active and Spindle Speed is NOT 100%)
* Spare Output Relay 47 (Control is in EDIT mode)
144 Feed Overide->Spindle
This setting is intended to keep the chip load constant when an override is applied. When this setting is ON, any
feedrate override will also be applied to the spindle speed, and the spindle overrides will be disabled.
146 APC Pallet 3 Load X
147 APC Pallet 3 Load Y
148 APC Pallet 3 Unload X
149 APC Pallet 3 Unload Y
Summary of Contents for Mill
Page 12: ...96 8000 rev R June 2007 Safety 5 ...
Page 14: ...96 8000 rev R June 2007 Safety 7 LATHE WARNING DECALS ...
Page 15: ...8 Safety 96 8000 rev R June 2007 ...
Page 17: ...10 Introduction 96 8000 rev R June 2007 ...
Page 117: ...110 4 5 Axis Programming 96 8000 rev R June 2007 ...
Page 199: ...Settings 192 96 8000 rev R June 2007 ...