TLC2100SHD Operating Instructions
Document 900.0060 Rev 1.01
49
Pin 11 Tape End Out
When in RECORD mode (not in Recycle Record, however), the output gets pulled to
+12V when end-of-tape occurs and is latched in this mode until the tape is ejected from
the recorder. This output can supply 10mA at +12V.
Pin 12 Camera Switcher Pulse Out
This TTL output is programmable via the on-screen display and the Record/Play buttons
on the front panel. It is intended to be connected to an external camera switcher and
causes the switcher to cycle through the cameras connected to it.
Pin 13 Remote In
Accepts a contact closure to Ground through a resistor network to activate various
modes. Different modes are activated depending on the resistance to Ground at the pin.
See
Appendix B, Remote Control Feature
, for more information.
Pins 14 and 15 Common
Connected to common system Ground. Used as a reference level for all inputs and
outputs on this connector.