TLC2100SHD Operating Instructions
Document 900.0060 Rev 1.01
7
5.
Sharpness
Use this control to adjust picture sharpness during playback.
6.
2-A24 Hour Tracking/6-A30 Hour Tracking
Adjust to optimize the picture quality playback speeds of 2 to A24 hours for
normal play and 6 to A30 hours in the High-Density (HD) mode.
7.
Slow Tracking
Adjust to optimize the picture quality during slow playback speeds, that is, speeds
of 24 hours and over for normal play and speeds of 30 hours and over in the HD
mode.
8.
V-LOCK
Adjust this control to reduce vertical jitter in the STILL mode.
Play/Record Operation Controls
Figure 2-5
Play/Record Operation Controls
9.
Field Reverse
Press to reverse the tape by one field in the STILL playback mode.
10. Still
Press to temporarily stop tape motion in the PLAY mode.
11. Field Forward
Press to advance the tape one field in the STILL playback mode.
EJECT
REC
FIELD
REV
STILL
FIELD
FWD
REVERSE
PLAY
REW/
SEARCH
F. FWD/
SEARCH
9
10
11
12
13
14
Follow this procedure for
the best results when
reviewing a timelapse
recorded tape:
•
With the VCR in
PLAY (#16), and
without a particular
event in mind, place the
VCR in the 2-hour
speed. This is the
fastest playback speed
and can usually be used
quickly to locate an
event.
•
Once an event has
been identified, slow
the unit to 24 hours, 48
hours or any other
slower speed. These
slower speeds will
allow close
examination of the
situation and ample
time to react.
•
Select the STILL
(#10) mode to stop the
tape. Use FIELD FWD
(#11) or FIELD REV
(#9) to get the exact
field you wish to
review.