PSU Series Programming Manual
144
Instrument
Summary
Registers
The Instrument Summary Registers indicate if the
protection mode or limit of any of the instruments
connected in Multi-Drop mode has been tripped.
CONDITION
EVENT
ENABLE
0
0
0
0
SRQ28
1
1
1
SRQ29
2
2
2
SRQ30
3
3
3
0
4
4
4
0
5
5
5
0
6
6
6
0
7
7
7
0
8
8
8
0
9
9
9
0
10
10
10
0
11
11
11
0
12
12
12
0
13
13
13
0
14
14
14
0
15
15
15
STATus:QUEStionable:ISUMmary3:CONDition?
STATus:QUEStionable:ISUMmary3:ENABle <NRf>
STATus:QUEStionable:ISUMmary3:ENABle?
CONDITION
EVENT
ENABLE
ISUM3
0
0
0
SRQ14
1
1
1
SRQ15
2
2
2
SRQ16
3
3
3
SRQ17
4
4
4
SRQ18
5
5
5
SRQ19
6
6
6
SRQ20
7
7
7
SRQ21
8
8
8
SRQ22
9
9
9
SRQ23
10
10
10
SRQ24
11
11
11
SRQ25
12
12
12
SRQ26
13
13
13
SRQ27
14
14
14
0
15
15
15
STATus:QUEStionable:ISUMmary2:CONDition?
STATus:QUEStionable:ISUMmary2:ENABle <NRf>
STATus:QUEStionable:ISUMmary2:ENABle?
CONDITION
EVENT
ENABLE
ISUM2
0
0
0
SRQ0
1
1
1
SRQ1
2
2
2
SRQ2
3
3
3
SRQ3
4
4
4
SRQ4
5
5
5
SRQ5
6
6
6
SRQ6
7
7
7
SRQ7
8
8
8
SRQ8
9
9
9
SRQ9
10
10
10
SRQ10
11
11
11
SRQ11
12
12
12
SRQ12
13
13
13
SRQ13
14
14
14
0
15
15
15
STATus:QUEStionable:ISUMmary1:CONDition?
STATus:QUEStionable:ISUMmary1:ENABle <NRf>
STATus:QUEStionable:ISUMmary1:ENABle?
To Instrument Summary in Questionable Condition register (bit 14)
ISUM3
Logical OR
ISUM2
Logical OR
STATus:QUEStionable:ISUMmary3[:EVENt]?
STATus:QUEStionable:ISUMmary2[:EVENt]?
STATus:QUEStionable:ISUMmary1[:EVENt]?
Logical OR
ISUM1
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+