REMOTE CONTROL
53
11.
Set the address of the master unit using the
F-76 parameter.
F-76 = 00~30
Set the address of the unit. It must
be a unique address identifier.
12.
You can check the slaves’ addresses by using
the F-77 parameter on the master unit.
F-77 = 3
Display on each slave units the
configured address. This can show if
identical addresses have been
assigned individually to each slave
units.
13.
Set the Multi-Drop setting parameter (F-77) to
Master.
F-77 = 1
Set the Multi-Drop setting to
master.
14.
You can display the status of each slave unit by
using the F-78 parameter.
F-78 = 0~30
Displayed parameter: AA-S
AA: 00~30 (Address),
S: 0~1 (Off-line/On-line status).
15.
Multiple units can now be operated using SCPI
commands. See the programming manual or see
the function check below for usage details.