PSU Series Programming Manual
162
PSU Factory Default Settings
The following default settings are the factory configuration settings
for the power supply (Function settings/Test settings).
Initial Settings
Default Setting
Output
Off
LOCK
0 (Disabled)
Voltage
0V
Current
0A
OVP
1.1 X Vrate
OCP
1.1 X Irate
Normal Function
Settings
Setting Default Setting
Output ON delay time
F-01
0.00s
Output OFF delay time F-02
0.00s
V-I mode slew rate select F-03
0 = CV high speed priority
Internal resistance
setting
F-08
0.000
Ω
Bleeder circuit control
F-09
1 = ON
Buzzer ON/OFF control F-10
1 = ON
OCP Delay Time
F-12
0.1 (seconds)
Current Setting Limit
F-13
0 = OFF
Voltage Setting Limit
F-14
0 = OFF
Display Memory
parameter when recalling
F-15
0 = OFF
Auto parallel Control
F-16
0 = OFF
Measurement Average
Setting
F-17
0 = Low
Alarm Recovery and
Output Status
F-18
0 = Safe Mode
Lock Mode
F-19
0:Lock Panel, Allow Output OFF
USB / GPIB setting
Setting Default Setting
Setup Rear USB Speed
F-22
2 = Auto detect
GPIB address
F-23
8
GPIB Enable/Disable
F-24
1 = Enable
SCPI Emulation
F-26
0 = GW Instek
LAN setting
Setting Default Setting
LAN
F-36
1 = Enable
DHCP
F-37
1 = Enable