REMOTE CONTROL
147
Positive Transition
0
→
1
Negative Transition
1
→
0
Event Register
The PTR/NTR Register will dictate the type of
transition conditions will set the corresponding
bits in the Event Register. If the Event Register is
read, it will be cleared to 0.
Enable Register
The Enable register determines which registered
Events in the Event Register will be used to set the
OPER bit in the Status Byte Register.