REMOTE CONTROL
141
Questionable Status Register Group
Overview
The Questionable Status Register Group indicates
if any protection modes or limits have been
tripped.
Condition
OV
0
PTR/NTP
Event
Enable
OC
1
Not Used
2
POW
3
OTP_M
4
OTP_S
5
FAN
6
Not Used
7
VL
8
CL
9
Not Used
10
SD
11
PL
12
SA
13
IS
14
Not Used
15
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Questionable Status Register
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
Logical OR
To Status Byte Register
STATus:QUEStionable:CONDition? STATus:QUEStionable:EVENt?
STATus:QUEStionable:NTRansition <NRf>
STATus:QUEStionable:NTRansition?
STATus:QUEStionable:PTRansition <NRf>
STATus:QUEStionable:PTRansition?
STATus:QUEStionable:ENABle <NRf>
STATus:QUEStionable:ENABle?
Bit Summary
Event
Bit # Bit Weight
OV (Over-Voltage)
Over voltage protection has been
tripped
0
1
OC (Over-Current)
Over current protection has been
tripped
1
2
POW (AC Power Off)
AC power switch is off
3
8