REMOTE CONTROL
133
Example
GLOB:VOLT MIN
Sets the voltage to the minimum for all units.
:GLOBal:OUTPut[:STATe][:IMMediate]
Set
Description
Sets output on or off for all units when using the
(Legacy) Multi-Drop mode.
Syntax
:GLOBal:OUTPut[:STATe][:IMMediate]
<bool>|OFF|ON
OFF | 0
Turns the output off for all units.
ON | 1
Turns the output on for all units.
Example
GLOB:OUTP OFF
Sets the output off for all units.
:GLOBal:PRESet
Set
Description
Loads the preset default settings for all units when
using the (Legacy) Multi-Drop mode.
Syntax
:GLOBal:PRESet