GETTING STARTED
31
CC Control
F-91
0 = Control by Local
1 = Control by External Voltage
2 = Control by External Resistor -
Rising
3 = Control by External Resistor -
Falling
4 = Control by Isolated Board
Output Status when
Power ON
F-92
0 = Safe Mode (Always OFF),
1 = Force Mode (Always ON),
2 = Auto Mode (Status before last
time power OFF)
Master/Slave
Configuration
F-93
0 = Independent
1 = Master with 1 slave in parallel
2 = Master with 2 slaves in parallel
3 = Master with 3 slaves in parallel
4 = Slave (parallel)
External Output Logic
F-94
0 = High ON, 1 = Low ON
Monitor Voltage Select
F-96
0 = 5V , 1 = 10V
Control Range
F-97
0 = 5V [5k
Ω
], 1 = 10V [10k
Ω
]
External Output Control
Function
F-98
0 = OFF, 1 = ON
Trigger Input and Output Configuration Settings
Trigger Input Pulse Width F100
0~60ms. 0 = trigger controlled by
trigger level.
Trigger Input Action
F102
0 = None
1 = Output ON/OFF (refer to F103)
2 = Setting (refer to F104 & F105)
3 = Memory (refer to F106)
Output State When
Receiving Trigger
F103
0 = OFF
1 = ON
Apply Voltage Setting on
Trigger
F104
0 ~ rated voltage (only applicable
when F102 =2)
Apply Current Setting on
Trigger
F105
0 ~ rated current (only applicable
when F102 =2)
Recall memory number
F106
1 ~ 3 (M1 ~ M3)
Trigger Output Pulse
Width
F120
0 ~ 60ms. 0 = trigger output is set to
the active level, not pulse width.
Trigger Output Level
F121
0 = LOW, 1 = HIGH (if F120 = 0)