:ACQuire:FILTer
Description
Turns the filter on/off or queries its status.
Note
This command is only applicable when the Digital
Filter app is installed. See the user manual for details.
Syntax
:ACQuire:FILTer {ON|OFF|?}
Parameter/
Return parameter
ON
Filter on.
OFF
Filter off.
Example
:ACQuire:FILTer?
OFF
Indicates that the filter is turned off.
:ACQuire:FILTer:FREQuency
Description
Sets or queries the filter frequency.
Note
This command is only applicable when the Digital
Filter app is installed. See the user manual for details.
Syntax
:ACQuire:FILTer:FREQuency {DEFault|<NRf>|?}
Parameter/
Return parameter
DEFault
Sets the filter frequency to the default.
<NRf>
Manually sets the filter frequency.
(1Hz ~ 500MHz)
Example
:ACQuire:FILTer:FREQuency 1
Sets the filter frequency to 1Hz.
:ACQuire:FILTer:TRACking
Description
Turns filter tracking on/off or queries its state.
Note
This command is only applicable when the Digital
Filter app is installed. See the user manual for details.
Syntax
:ACQuire:FILTer:TRACking {ON|OFF|?}
Parameter/
OFF
Tracking off
Set
Query
Set
Query
Set