![GW Instek GDS-1000B Series Programming Manual Download Page 130](http://html1.mh-extra.com/html/gw-instek/gds-1000b-series/gds-1000b-series_programming-manual_2280038130.webp)
GDS-1000B Programming Manual
130
Syntax
:TRIGger:DELay:EVENt {<NR1> | ?}
Related
commands
:TRIGger:DELay:TYPe
Parameter
<NR1>
1~65535 events
Return parameter <NR1>
Returns the number of events.
Example
:TRIGger:DELay:EVENt 2
Sets the number of events to 2.
:TRIGger:DELay:LEVel
Description
Sets or queries the trigger delay level.
Syntax
:TRIGger:DELay:LEVel {<NRf> | ?}
Parameter
<NRf>
Delay trigger level
Return parameter <NR3>
Returns the delay trigger.
Example
:TRIGger:DELay:LEVel 5.00E-3
Sets the delay trigger level to 5mV/mA.
:TRIGger:PULSEWidth:POLarity
Description
Sets or queries the pulse width trigger polarity.
Syntax
:TRIGger:PULSEWidth:POLarity
{POSitive | NEGative | ?}
Related
commands
:TRIGger:TYPe
Parameter
POSitive
Positive polarity
NEGative
Negative polarity
Return parameter
Returns the pulse width polarity.
Example
:TRIGger:PULSEWidth:POLarity POSitive
Sets the pulse width polarity to positive.
Set
Query
Set
Query