74
©2016 Guangzhou ZHIYUAN Electronics
Date: 2016/12/08
User Manual
V1.00
C
Guangzhou ZHIYUAN Electronics Co., Ltd.
PA5000 Series Power Analyzer Start Guide
Figure 6-21: Configure the numerator and denominator for a
η formula
(4) Configure Udef1 or Udef2
When the sum of several calculation items needs to be used as the numerator or
denominator of an efficiency formula, users can select Udef1 or Udef2 as the numerator
or denominator, and configure Udef1 or Udef2. The Udef1 can be set as the sum of
individual power, as shown in Figure 6-22.
Figure 6-22: Efficiency calculation items setting
3. Note
The efficiency calculation cannot be performed in the IEC harmonic measurement
mode, voltage fluctuation and flick measurement mode, and cycle analysis mode.
Please make sure that all the power values used for efficiency calculation have same
unit.
4. Supplemental Information
The examples of efficiency formula are described as follows:
Figure 6-23: Efficiency formula