Installation & User Manual – Oncam C-12 Series
©
Oncam Global Group AG, 2021. All rights reserved.
80
4.1.1.1.3 Static IP
The camera can be configured with a manual Static IP Address. This will also require the
Gateway to be set to allow communication with the outside network, and DNS addresses to
resolve DNS names if required. On first time setup, the camera will need to be discovered using
DHCP or Link Local as described above. The Primary Administrator will need to create login
credentials, log-into the camera and set up the Static IP Address. This can be configured in the
Camera Web Interface;
Network > Network Configuration
.
If the camera is configured with a Static IP Address on a different subnet than the local
network, either use the camera’s Link Local address, which will be provided in discovery,
or simply force a Physical Reset to Factory Defaults
See Section 5.8.3.3 Reset to Factory
Defaults
4.1.1.2 Camera Configuration Tool (CCT)
4.1.1.2.1 Download
To discover the camera's IP Address, download the C- Series Camera Configuration Tool from
https://www.oncamgrandeye.com/resources/c-series-camera-config-tool/
Please ensure you meet the minimum system requirements and have the latest Edge
Browser (90 or above) installed.
4.1.1.2.2 Installation
Follow the on-screen instructions to install the application.
4.1.1.2.3 Discovery
Open the Camera Configuration Tool on a PC that is on the same network as the cameras. As
soon as the App is initiated it will discover the Oncam C-Series cameras on your network and
display key information including the Friendly name, Model number, MAC Address and most
importantly the IP Address of the camera. To update the list, select
Refresh Discovery icon
in the top right-hand corner.
The discovered camera list is displayed on initiation of the Camera Configuration Tool,
and then only when the Refresh discovery icon is manually selected.
The Link local address is not currently discoverable using the C-Series Camera
Configuration Tool.