English (GB)
16
5.2 Connecting the dosing regulator
Fig. 14
Vacuum connections
The dosing regulator can be installed outside the chlorine room.
1. Connect the dosing regulator to the line from the vacuum
regulator (1).
2. Connect the line (3) from the dosing regulator, or from the
optional differential pressure regulator, to the injector.
5.3 Connecting an external controller to a servomotor
with analog control
5.3.1 Warnings and notes for electrical connection
5.3.2 Circuit diagram servomotor with analog control
Fig. 15
Servomotor with analog control
5.3.3 Connecting the external controller Conex
®
DIA-2Q
Connect the terminals of the servomotor according to the terminal
connection diagram of the controller.
Fig. 16
Terminal connection diagram Conex
®
DIA-2Q
Warning
Before connecting, make sure that the valves of all
chlorine containers are closed.
TM
0
4
8
413
1
8
11
Pos. Description
1
Vacuum line to the dosing regulator
2
Overpressure line
3
Vacuum line to the injector
Caution
For details on vacuum lines, see section
Only tighten the union nuts of the vacuum
connections by hand. Do not use any tools. Danger
of damages!
Make sure that the vacuum connections are clean
and dry.
2
3
VGA-111
1
Warning
Disconnect servomotor from mains before
removing the cover.
Observe the local safety regulations.
Protect unused screwings, cable connections and
plugs against corrosion and moisture with suitable
caps.
Caution
To ensure electromagnetic compatibility (EMC) signal
lines must be shielded, and guided in different cable
channels than mains cables.
The shield must be connected to PE or ground on the
side of the counterpart.
Caution
Before connecting the mains cable check, if the
mains voltage indicated on the type plate
corresponds to the local mains voltage. Wrong
voltage can lead to damages of the servomotor.
Note
Depending on the optional components selected,
connect mains plug to mains directly or via the
terminal box.
TM
04
09
51
40
09
Warning
See section
5.3.1 Warnings and notes for electrical
for warnings and notes relating to
electrical connection.
T
M
04
09
51
40
09
4(0) - 20 mA
max. 125 V
56
57
55
54
52
51
-
+
+
L
N
L1
N
PE
-
Error message
30 29
Conex DIA-2Q
4(0) - 20 mA
max. 125 V
56
57
55
54
52
51
-
+
+
L
N
L1
N
PE
-
Error message