10. Commissioning / electrical
connections
1. Remove the terminal cover on the front of the
device.
2. Use the appropriate cable feedthroughs and
tighten the screws carefully.
3. Connect the cables used to the terminals
according to the
Conex
®
DIA-2
terminal
assignment.
4. Close the terminal cover again with correctly
positioned gasket.
Warning
Switch off the power supply before
installing!
Enclosure class IP65 is only guaranteed with
the front panel of the terminals enclosure
closed and with appropriate cable glands or
dummy caps.
Warning
Switch off the power supply before
connecting the power supply cable and
relay contacts! For safety reasons, the
protective conductor must be connected
correctly!
Observe the local safety regulations!
Protect the cable connections and plugs
from corrosion and moisture.
Caution
Before connecting the power supply cable,
check that the supply voltage specified on
the nameplate corresponds to the local
conditions!
An incorrect supply voltage may destroy
the device!
To guarantee electromagnetic compatibility
(EMC), the input and current output cables
must be screened.
Connect the screening to the screen
ground on one side.
Refer to the wiring diagram! Route the
input, current output and power supply
cables in separate cable channels.
Caution
Enclosure class IP65 is only guaranteed if
the terminal cover is correctly sealed! Do
not damage the gasket on the terminal
cover!
The gasket on the terminal cover must be
positioned precisely!
Do not damage the gasket!
Note
Unused terminals must
remain open.
Summary of Contents for Conex DIA-2
Page 2: ...2...
Page 456: ...RU 456 2 Conex DIA 2 1 2 pH Conex DIA 2 PID...
Page 459: ...RU 459 4 Conex DIA 2 GRUNDFOS 5 Conex DIA 2 Cl2 ClO2 O3 H2O2 pH 6 6 1 Conex DIA 2 6 2 GRUNDFOS...
Page 468: ...RU 468 10 1 2 3 Conex DIA 2 4 IP65 IP65...
Page 481: ...RU 481 11 4 1 OK Esc 10 AQC D2 D12 Cal Man Cal Man Cal Man...
Page 488: ...RU 488 11 6 11 6 1 30 1 2 Up Down OK TM03 6734 4506 1 2 2 1 P PI PID...
Page 489: ...RU 489 1 Up Down OK 2 Up Down OK 3 Up Down OK 4 Up Down OK 5 Up Down P PI PID OK...
Page 492: ...RU 492 11 6 4 PI PID 1 33 2 Man 20 20 3 4 OK Esc 5 OK Esc TM03 6715 4506 0 43 pH...
Page 493: ...RU 493 11 7 34 TM03 6737 4506 1 2 1 1 2 2 2 1...
Page 495: ...RU 495 11 8 OK 35 TM03 6738 4506 5 1 10 1 pH 2 4 1 1 1 3 1 4 1 2 0 4 A 10 A 20 A 2 3...
Page 499: ...RU 499 120 pH 50 62 pH 60 60 OK 25 C 1 2 Cal pH OK pH 3 OK 4 C F 5 OK 1 100 25 C...
Page 501: ...RU 501 11 10 1 Man 2 Up Down Man 3 0 4 Man 11 10 1 38 TM03 6721 4506 Man 1 0 100 2 0 100...
Page 503: ...RU 503 11 10 2 39 OK 11 6 3 TM03 6721 4506 Man 1 2 0 100...
Page 504: ...RU 504 12 1 a 2 pH pH 7 a 3 a 4 a b pH c pH d e 5 a 6 pH a b 7 pH a b c 8 a 11 5 8 9 a...
Page 505: ...RU 505 13 14 GRUNDFOS GRUNDFOS 15 24 GRUNDFOS...
Page 608: ...608...
Page 609: ...609...