Fault
60 | 76
9.2
Other observations
Observation
Meaning
Remedy
No soft water
Excessive water
consumption
(water softener has
exceeded its capacity).
Restrict your water consumption to
the maximum flow rate permitted
(refer to chapter 12).
Perform a manual regeneration (refer
to chapter 7.2).
Water softener does not
have a permanent
power connection.
Check the electrical power
connection.
Soft water meter is not
emitting pulses.
Notify Grünbeck's technical service/
authorised service company.
Raw water hardness set
too low.
Measure the raw water hardness
(refer to chapter 7.7).
Check the value in the control unit
(refer to chapter 7.7).
Water supply
interrupted.
Open the shut-off valves.
Resin pellets in the
rinsing water hose or
sparkler
Defective jet system.
Notify Grünbeck's technical service/
authorised service company.
Water pressure at the
withdrawal point too
low.
(Pressure loss too
high.)
Resin may be polluted
by undissolved particles.
Check if the problem originates from
the water softener.
If yes, notify Grünbeck's technical
service/authorised service company.
Adsorber blocked.
Notify Grünbeck's technical service/
authorised service company.