Fault
59 | 76
Display
Explanation
Remedy
Regeneration water meter
Quantity not reached!
Observe operation manual!
Regeneration water
meter is not emitting
pulses.
Connecting cable
defective.
Water supply
interrupted.
Symbol on the left: Exchanger 1
Symbol on the right: Exchanger tank
2
Check the water supply.
Notify Grünbeck's technical service/
authorised service company.
Check soft water meter!
Observe operation manual!
Soft water meter is not
emitting pulses.
Connecting cable
defective.
Water supply
interrupted.
Symbol on the left: Exchanger 1
Symbol on the right: Exchanger tank
2
Check the water supply.
Notify Grünbeck's technical service/
authorised service company.
Check regeneration water
meter!
Observe the operation manual
Regeneration water
meter is not emitting
pulses.
Connecting cable
defective.
Water supply
interrupted.
Symbol on the left: Exchanger 1
Symbol on the right: Exchanger tank
2
Check the water supply.
Notify Grünbeck's technical service/
authorised service company.
Check blending water meter!
Observe the operation manual
Blending water meter
does not provide any
impulses.
Connecting cable
defective.
Water supply
interrupted.
Check the water supply.
Notify Grünbeck's technical service/
authorised service company.
System is not drawing brine
from the brine tank effectively!
Observe operation manual!
Minimum contact during
salting not reached.
Monitoring time
exceeded.
Injector clogged or raw
water pressure too low.
Symbol on the left: Exchanger 1
Symbol on the right: Exchanger tank
2
Notify Grünbeck's technical service/
authorised service company.
Nominal flow rate
exceeded!
Appears if during a
regeneration if a flow
rate of 1.0 m³/h is
exceeded or during
standard operation if a
flow rate of 2.0 m³/h is
exceeded.
Only displayed if monitoring is
activated. Reduce peak flow.
If the error occurs continuously, notify
Grünbeck's technical service/
authorised service company.