Installation
36 | 76
5.2
Check the scope of supply
No.
Description
No.
Description
1
Water softener completely pre-assembled
4
Water test kit "total hardness“
2
2 Connection hoses
5
Operation manual
3
Connection block incl. 2 inserts, union nuts, seals
each
► Check the scope of supply for completeness and possible damage.
5.3
Installing the product
WARNING:
Danger of contaminated drinking water due to stagnation.
● Risk of infectious diseases.
► In accordance with VDI 6023, do not connect your product to the drinking water
installation until immediately prior to start-up.
WARNING:
Danger of not completely disinfected drinking water.
● There is a danger that the drinking water will not flow completely through the
system with a connection block provided by the customer.
► Always use the supplied connection block.
Do not install the connection block until immediately before commissioning, or bypass it
with a hose. There is no overflow valve in the connection block, so water cannot flow
without a connected system.
2
5
3
4
1