Cleaning, inspection, maintenance
54 | 76
11.
Read off the residential water meter reading.
12.
Read off the regeneration counter (information 3).
13.
Read off soft water volume meter (information 3).
14.
Read out the error memory (code 245).
Preliminary maintenance work
15.
Check the hose connections for leaks and damage.
16.
Check that all cables and connections are undamaged and firmly seated.
17.
Check salt tablets for impurities.
18.
Clean the brine tank.
19.
Clean and check the brine valve and level electrodes.
Maintenance work on the roads
The work described below needs to be carried out on each of the sections.
Starting from “Release manual regeneration”, we recommend carrying out the
work in parallel.
20.
Change of the adsorbers:
a
Select the adsorber service program.
b
Press ENTER to confirm.
21.
Check soft water meter for pulse emission (Code 005).
22.
Check the injectors and injector sieves for impurities and clean, if necessary.
23.
Check the brine filling orifices in the brine connection angles (red).
24.
Move to the reference positions (code 005).
25.
Release a manual regeneration.
26.
Check the suction performance of the injectors.
27.
Check the chlorine currents during salting (regeneration step 2) (Code 245).
28.
Check the function of the regeneration water meter in any regeneration step (Code
005).
29.
Check the control valves at the drain outlet in operational position for leaks
(flushing water hose Ø 12mm).
30.
Check the filling and suction hoses to the brine valves for leaks.
31.
Check flushing water hose for leaks.
32.
Release a double regeneration (Code 005).
33.
After the cleaning of the brine tank, fill in the operating water volume (Code 005).