Control unit
23 | 76
4.5
Code-protected levels
The settings described here may only be performed by specialist installers or Grünbeck's
technical customer service/authorised service company.
Status level>Menu level>Customer service
1.
Touch ENTER briefly.
2.
Enter the code with ▼ and ▲.
3.
Confirm with ENTER.
4.5.1
Installer level (code 005)
The settings described here may only be performed by specialist installers or Grünbeck's
technical customer service/authorised service company.
Additional parameters and values can be modified in the extended installer level:
Menu items
Settings/remarks
Information
exchanger
tank 1
(indication only)
Current flow [m³/h]
Remaining capacity [m³]
Regeneration step [min.] or [l]
Last regeneration [date/time] via xx [%]
Information
exchanger 2
(indication only)
As for exchanger 1
Blending
information
Current flow [m³/h]
Index value of soft water
Actual value of soft water
Actual raw water hardness
Flow rates
(indication only)
Parallel operation
Peak value x.xx [m³/h] for xxxxx [min.]
Exchanger 1
Peak value x.xx [m³/h] for xxxxx [min.]
Exchanger 2
Peak value x.xx [m³/h] for xxxxx [min.]
Soft water
sample
Exchanger tank 1
0 - Factory-setting
1 - Carry out function.
Exchanger 2
0 - Factory-setting
1 - Carry out function.
Perform soft water sampling for selected exchanger. After completion,
the factory-setting is activated again.