Reverse osmosis system
AVRO 125 TS/TL
Order no. 185 752 945-inter Edited by: nkes-mrie :\BA-752945-INTER_185_AVRO_125.DOCX
35
2.1 Reading the
operating status
Various operating parameters can be displayed in the information level.
The information level is accessed by pressing the button (> 5 s).
The other parameters are accessed by touching. The information level
remains locked for as long as the system has not been enabled using
the close input signal.
Button Display
Parameter
00:00
Basic time display
The system might still be switched on with the first press (> 5 s)!
365
Remaining duration of the service interval [days]
3000 Remaining
time
AVRO
maintenance interval
[operating hours]
LF022
Permeate conductivity [µS/cm] (optional –
display value flashes if the advance warning
value is exceeded)
P0200
Permeate flow rate [l/h]
c0200
Concentrate flow [l/h]
u0320
Flow rate blending [l/h] (option 752 800)
A 050
System recovery [%]
2.2 How to set the
time
Requirement:
Basic time display is currently being displayed.
1.
Press button > 2.5 seconds, only the hours are still displayed 00:
2.
Press button to change the hours (value is flashing, now set the
desired value with or buttons and save with the button)
or
press button to advance to the minutes :00.
3.
Press button to change the minutes (value is flashing, now
set the desired value with or buttons and save with the
button).
4.
Return to the basic display time by simultaneously pressing
and buttons.