G0620 Main Control Panel
Calibrating the
Display
The controller can be calibrated to match the
actual measured distance from the blade to the
controller flip stop. This calibration is critical to
ensure that cutting results with the crosscut fence
are accurate.
To calibrate the controller:
1.
Move the flip stop to the side of the fence that
would touch the workpiece, and measure the
distance between the flip stop and the blade.
2.
Press the ABS/REL key, then release it to
make sure the controller is in the ABS mode.
3.
Press and hold the CLR/SET
���
���
key (the
sign will appear), then press and release the
ABS/REL key, then release the CLR/SET
���
���
key.
The controller will display a small flashing "0",
which signals that it is ready to accept input
(see
Figure 34
).
5.
Press the F/ENTER
�
�����
key to save the cur-
rent number in the controller as the "cali-
brated" measurement. The controller is now
calibrated to be accurate from the flip stop to
the saw blade.
— If the calibrated distance is shown on the
display, no further steps are necessary.
— If the calibrated number is not shown, con-
tinue to
Step 6
.
6.
Press the ABS/REL key, then release it to
make sure the controller is in the ABS mode.
7.
Press and hold the F/ENTER
�
�����
key (the
sign will appear while this key is held down),
then press and release the CLR/SET
���
���
key,
then release the F/ENTER
�
�����
key.
���
������� �������
�
�����
���
���������
���
Figure 34.
Display screen ready to accept
numerical input for calibration.
4.
Use the left and right arrows on the ABS/REL
and mm/inch
�������
keys to choose which dig-
its to modify.
Modify the digits by pressing the CLR/SET
���
���
key when the chosen digit is blinking. When
you are done, the number on the controller
should match the measurement you took in
Step 1
(see
Figure 35
for confirmation).
���
������� �������
�
�����
���
���������
���
Figure 35.
Numerical input of 8" entered for
calibration.