48
Low fan
Low-Medium fan
Medium fan
Medium-High fan
High fan
Note
: It’s Low fan speed under Dry mode.
4)
TEMP
Press this button, the following temperature can be set circularly: the setting temperature, indoor ambient
temperature and outdoor ambient temperature. When the indoor unit firstly power on, it will display the setting
temperature
. If the displaying status is changed to
, displaying the indoor ambient temperature.
is the
outdoor ambient temperature. 5s(3s) later it will return to the setting temperature or it depends on the other
received signal within 5s(3s).
Note:
Outdoor ambient temperature display range is 0~60
℃
(32~99
℉
). As for the outdoor ambient
temperature below 0 it displays 0
℃
(32
℉
).
“
”
function is applicable to partial of models.
Warm tips:
When operating buttons on the cover, please make sure the cover is closed completely.
5)
CLOCK :
Press this button, the clock can be set up, signal
blink and display. Within 5 seconds, the value can be
adjusted by pressing
+
or
-
button, if continuously press this button for 2 seconds above, in every 0.5seconds,
the value on ten place of Minute will be increased 1. During blinking, repress the Clock button or Confirm button,
signal
will be constantly displayed and it denotes the setting succeeded. After powered on, 12:00 is
defaulted to display and signal
will be displayed. If there is signal
be displayed that denotes the current
time value is Clock value, otherwise is Timer value.
6)
LIGHT:
Press LIGHT button at unit On or Off status, Light On and Light Off can be set up. After powered on, Light
On is defaulted.
7)
TURBO:
Under Cool or Heat mode, press this button can turn on or turn off the Turbo function. After the Turbo
function turned on, the signal of Turbo will display. The signal will be automatically cancelled if changing the
mode or fan speed.
8)
X-FAN:
Pressing X-FAN button in COOL or DRY mode, the icon
is displayed and the indoor fan will continue
operation for 10(2) minutes in order to dry the indoor unit even though you have turned off the unit. After
energization, X-FAN OFF is defaulted. X-FAN is not available in AUTO, FAN or HEAT mode.
9)
+:
Presetting temperature can be increased. Press this button, the temperature can be set up, continuously press
this button and hold for two seconds, the relative contents can quickly change, until unhold this button and send
the order that the
℃
(
℉
) signal will be displayed all the time. The temperature adjustment is unavailable under
the Auto mode, but the order can be sent if pressing this button. Temperature of Celsius degree setting: 16-30;
Summary of Contents for R410A
Page 1: ...SUPER FREE MATCH SERIES SERVICE MANUAL T1 R410A 50Hz GC201306 CENTRAL AIR CONDITIONERS ...
Page 5: ...Super Free Match Service Manual PRODUCT 1 PRODUCT ...
Page 28: ...Super Free Match Service Manual CONTROL 24 CONTROL ...
Page 29: ...Super Free Match Service Manual CONTROL 25 Control 1 OPERATION FLOWCHART ...
Page 31: ...Super Free Match Service Manual CONTROL 27 1 2 Heating Operation ...
Page 66: ...Super Free Match Service Manual INSTALLATION 62 INSTALLATION ...
Page 97: ...Super Free Match Service Manual INSTALLATION 93 ...
Page 129: ...Super Free Match Service Manual MAINTENANCE N 125 MAINTENANCE ...
Page 153: ...Super Free Match Service Manual MAINTENANCE N 149 4 2 3 BU module FXB3A K ...
Page 154: ...Super Free Match Service Manual MAINTENANCE 150 FXB5A K ...
Page 217: ...JF00301896 ...