Conditions Causes
When restart the unit soon after it
is stopped
The overload protection switch of the unit let the
startup delayed for three minutes
The unit does not run
As soon as power supply is on
The unit will stand by for approximate one minute
The unit blows out mist
When the cooling operation starts
The hi-humidity air indoor is cooled quickly
The unit “clatters” as soon as it
starts running
It is the sound generated during the initialization of
the electronic expansion valve
The unit “swishes” during the
cooling operation
It is the sound when the refrigerant gas runs inside
the unit
The unit “swishes” when it is
started or stopped
It is the sound when the refrigerant gas stops running
The unit “swishes” when it is in
and after the running
It is the sound when the draining system is operating
The unit generates noise
The unit “squeaks” when it is in
and after the running
It is the sound of frication generated by the skin plate
etc which swells due to the temperature change
The unit blows out dust
When the unit restarts after it is
not used for a long time
The dust inside the unit is blown out again
The unit emits odors
When the unit is running
The odors absorbed in are blown out
2.3
Error description
Outdoor unit
If some error occurs when the unit is running, the error code will be displayed on the wired controller, the
testing board
of the outdoor unit. Check for more details about the meaning of each error.
Main control display for outdoor unit
Errors of definition
Yellow LED
Red LED
Green LED
Indoor unit
code
Testing board
code
The compressor is startup
Flash 1 time
IPM current protection
Flash 3 times
H5 H5
IPM temperature protection
Flash 5 times
P8 P8
PFC current protection
Flash 7 times
HC HC
PFC temperature protection
Flash 8 times
P8 P8
Low voltage protection
Flash 9 times
PL PL
High voltage protection
Flash 10 times
PH PH
Low pressure protection
Flash 11 times
E3 E3
High pressure protection
Flash 12 times
E8 E8
High pressure switch protection
Flash 13 times
E1 E1
Capacitor charging error
Flash 14 times
PU PU
AC current protection
Flash 15 times
E5 E5
Memory card error
Flash 16 times
EE EE
Compressor demagnetizing protection
Flash 17 times
HE HE
Compressor desynchronizing
Flash 18 times
H7 H7
Compressor phase lack
Flash 19 times
U2 U2
Compressor phase circuit detection error
Flash 20 times
U1 U1
Compressor power protection
Flash 21 times
L9 L9
Compressor overload protection
Flash 22 times
H3 H3
Summary of Contents for R410A
Page 1: ...SUPER FREE MATCH SERIES SERVICE MANUAL T1 R410A 50Hz GC201306 CENTRAL AIR CONDITIONERS ...
Page 5: ...Super Free Match Service Manual PRODUCT 1 PRODUCT ...
Page 28: ...Super Free Match Service Manual CONTROL 24 CONTROL ...
Page 29: ...Super Free Match Service Manual CONTROL 25 Control 1 OPERATION FLOWCHART ...
Page 31: ...Super Free Match Service Manual CONTROL 27 1 2 Heating Operation ...
Page 66: ...Super Free Match Service Manual INSTALLATION 62 INSTALLATION ...
Page 97: ...Super Free Match Service Manual INSTALLATION 93 ...
Page 129: ...Super Free Match Service Manual MAINTENANCE N 125 MAINTENANCE ...
Page 153: ...Super Free Match Service Manual MAINTENANCE N 149 4 2 3 BU module FXB3A K ...
Page 154: ...Super Free Match Service Manual MAINTENANCE 150 FXB5A K ...
Page 217: ...JF00301896 ...