Super Free Match
Service Manual
PRODUCT
20
4.2.5 Console type
Model Heat
pump
GEH(09)AA-K3DNA1
C/I
GEH(12)AA-K3DNA1
C/I
GEH(18)AA-K3DNA1
C/I
Cooling KW
2.6 3.5 5.3
Capacity
Heating KW
2.8 3.8 5.8
Power supply
V-Ph-Hz
220~240-1-50
220~240-1-50
220~240-1-50
Motor power input
kW
0.05
0.05
0.05
m3/h
500 600 650
Air flow volume
CFM 294
353
383
Sound pressure level
(SH/H/MH/M/ML/L/SL)
dB(A)
40/38/36/33/30/27/25 42/40/38/37/35/32/25 48/46/44/41/37/35/32
Output kW
0.03
0.03
0.03
Fan motor
Running
current
A 0.14
0.14
0.14
Gas inch 3/8
″
(
Φ
9.52mm) 3/8
″
(
Φ
9.52mm) 1/2
″
(
Φ
12.7mm)
Liquid inch 1/4
″
(
Φ
6.35mm) 1/4
″
(
Φ
6.35mm) 1/4
″
(
Φ
6.35mm)
Connecting
pipe
Connection method
Flare Connection
Flare Connection
Flare Connection
External
dia.
mm
Φ
20
Φ
20
Φ
20
Drain pipe
Thickness mm
1.5
1.5
1.5
Outline
dimension
W×D×H mm
700×215×600 700×215×600 700×215×600
Package
dimension
W×D×H mm
791×286×710 791×286×710 791×286×710
Net Weight/Gross weight
kg
15/18 15/18 15/18
20'GP 168
168
168
40' GP
348 348 348
Loading quantity
40' HQ
440 440 440
Notes:
a. The rated cooling capacity data is measured under the following work condition: Indoor Temperature is 27
℃
DB, 19
℃
WB. Outdoor Temperature is 35
℃
DB. The rated heating capacity data is measured under the following
work condition: Indoor Temperature is 20
℃
DB. Outdoor Temperature is 7
℃
DB, 6
℃
WB.
b. The data will change with the change of products. Refer to those parameters listed on nameplate.
c. Noise was tested in semi-silenced room, so the actual noise value will be a little higher for change of ambient.
Summary of Contents for GKH(12)BA-K3DNA1A/I
Page 1: ...SUPER FREE MATCH SERIES SERVICE MANUAL T1 R410A 50Hz GC201405 CENTRAL AIR CONDITIONERS...
Page 5: ...Super Free Match Service Manual PRODUCT 1 PRODUCT...
Page 27: ...Super Free Match Service Manual CONTROL 23 CONTROL...
Page 28: ...Super Free Match Service Manual CONTROL 24 Control 1 OPERATION FLOWCHART...
Page 30: ...Super Free Match Service Manual CONTROL 26 1 2 Heating Operation...
Page 64: ...Super Free Match Service Manual INSTALLATION 60 INSTALLATION...
Page 122: ...Super Free Match Service Manual MAINTENANCE 118 MAINTENANCE...
Page 144: ...Super Free Match Service Manual MAINTENANCE 140 4 2 3 BU module FXB3A K...
Page 145: ...Super Free Match Service Manual MAINTENANCE N 141 FXB5A K...
Page 207: ...JF00301896...