Super Free Match
Service Manual
PRODUCT
10
¾
U-cool
Model
GWH(07)UA-K
3DNA1B/I
GWH(09)UA-K
3DNA1B/I
GWH(12)UB-K
3DNA1B/I
GWH(18)UC-K
3DNA1B/I
Cooling kW
2.1 2.6 3.5 5.3
Capacity
Heating kW
2.6 2.8 3.8 5.8
Power supply
V-Ph-Hz
220~240-1-50
220~240-1-50
220~240-1-50
220~240-1-50
Motor power input
kW
0.03
0.03
0.04
0.06
m3/h
450 450 560 850
Air flow volume
CFM 265
265
330
500
Sound pressure level
(SH/H/MH/M/ML/L/SL)
dB(A)
37/35/32/30/28/
26/24
38/35/32/30/28/
26/25
39/37/34/31/29/
27/26
44/40/37/35/33/
31/28
Output kW
0.01
0.01
0.02
0.025
Fan motor
Running
current
A 0.136 0.136
0.2
0.31
Gas inch
3/8
″
(
Φ
9.52mm)
3/8
″
(
Φ
9.52mm)
3/8
″
(
Φ
9.52mm)
1/2
″
(
Φ
12.7mm)
Liquid inch
1/4
″
(
Φ
6.35mm)
1/4
″
(
Φ
6.35mm)
1/4
″
(
Φ
6.35mm)
1/4
″
(
Φ
6.35mm)
Connecting
pipe
Connection method
Flare
Connection
Flare
Connection
Flare
Connection
Flare
Connection
External dia.
mm
Φ
20
Φ
20
Φ
20
Φ
20
Drain pipe
Thickness
mm
1.5 1.5 1.5 1.5
Outline
dimension
W×D×H mm
860×153×299 860×153×299 896×159×320 998×178×340
Package
dimension
W×D×H mm
944×247×386 944×247×386 973×255×403 1083×283×428
Net Weight/ Gross weight
kg
9.5/12.5 9.5/12.5 10/13 14.0/17.0
20'GP 324
324
279 216
40' GP
666 666 585 440
Loading quantity
40' HQ
740 740 650 495
Notes:
a. The rated cooling capacity data is measured under the following work condition: Indoor Temperature is 27
℃
DB, 19
℃
WB. Outdoor Temperature is 35
℃
DB. The rated heating capacity data is measured under the following
work condition: Indoor Temperature is 20
℃
DB. Outdoor Temperature is 7
℃
DB, 6
℃
WB.
b. The data will change with the change of products. Refer to those parameters listed on nameplate.
c. Noise was tested in semi-silenced room, so the actual noise value will be a little higher for change of ambient.
Summary of Contents for GKH(12)BA-K3DNA1A/I
Page 1: ...SUPER FREE MATCH SERIES SERVICE MANUAL T1 R410A 50Hz GC201405 CENTRAL AIR CONDITIONERS...
Page 5: ...Super Free Match Service Manual PRODUCT 1 PRODUCT...
Page 27: ...Super Free Match Service Manual CONTROL 23 CONTROL...
Page 28: ...Super Free Match Service Manual CONTROL 24 Control 1 OPERATION FLOWCHART...
Page 30: ...Super Free Match Service Manual CONTROL 26 1 2 Heating Operation...
Page 64: ...Super Free Match Service Manual INSTALLATION 60 INSTALLATION...
Page 122: ...Super Free Match Service Manual MAINTENANCE 118 MAINTENANCE...
Page 144: ...Super Free Match Service Manual MAINTENANCE 140 4 2 3 BU module FXB3A K...
Page 145: ...Super Free Match Service Manual MAINTENANCE N 141 FXB5A K...
Page 207: ...JF00301896...