Super Free Match
Service Manual
INSTALLATION
68
The place should be well-ventilated, so the machine can absorb and discharge sufficient air.
Outdoor unit shall be installed close to the indoor unit, hence to minimize the length and bends of
cooling pipe.
Avoid place the outdoor unit under the windows or between the constructions, hence to prevent normal
operating noise from entering the room.
Do not install in the place where there is flammable or explosive gas exist or a place subject to severe
dust, salty fog and polluted air.
Installation at the following places might lead to the air conditioner malfunction. If it is unavoidable, please
contact the appointed service center.
A place which is full of machine oil;
A region with saline-sodic soil near the sea;
A place where the sulphide fog exists, such as the sulphur spring;
A place where the high frequency facilities exist, such as radio equipment, electric welder and medical
equipment;
An environment with special conditions.
3.7
Outline Dimension of the Outdoor Unit
3.8
Installation and Servicing Space
1)
When the place of the installation is exposed to strong wind
When strong winds of 5 m/sec or more exist in the place of the installation, the outlet of the unit cannot face
the wind. If the wind blows against the outdoor unit's air outlet, it will cause deterioration of the operational
capacity and maybe break the fan.
2)
In case of installing only one unit
In case obstacles exist around the unit, the required installation space is in the following figure. The unit of the
values is mm.
3)
In case of installing multiple units(2 units or more)
In case multiple rows of series installation, the required installation space is in the following figure. The unit
of the values is mm.
Summary of Contents for GKH(12)BA-K3DNA1A/I
Page 1: ...SUPER FREE MATCH SERIES SERVICE MANUAL T1 R410A 50Hz GC201405 CENTRAL AIR CONDITIONERS...
Page 5: ...Super Free Match Service Manual PRODUCT 1 PRODUCT...
Page 27: ...Super Free Match Service Manual CONTROL 23 CONTROL...
Page 28: ...Super Free Match Service Manual CONTROL 24 Control 1 OPERATION FLOWCHART...
Page 30: ...Super Free Match Service Manual CONTROL 26 1 2 Heating Operation...
Page 64: ...Super Free Match Service Manual INSTALLATION 60 INSTALLATION...
Page 122: ...Super Free Match Service Manual MAINTENANCE 118 MAINTENANCE...
Page 144: ...Super Free Match Service Manual MAINTENANCE 140 4 2 3 BU module FXB3A K...
Page 145: ...Super Free Match Service Manual MAINTENANCE N 141 FXB5A K...
Page 207: ...JF00301896...