SRVC
Parameter
Options
Description
Tag
L/Out
LED Mode
LED Color
Latch LED
Backlight
Alarm
Fav
EXPERT BELOW
Modulation
Atten
Delay
Delay Time
Zeromatic
Search Dir
Hit Count
Alpha-numeric text
The alphanumeric display name for the SRVC
search. Use the standard text entry method or
QTXT to name the object.
On or Off
Permanent lockout for the SRVC object. Also
accessed by pressing
FUNC L/OUT
while the
scanner is stopped on the SRVC object.
Solid or Flash
Controls whether the ALERT LED flashes or
remains on solid when the ALERT LED is used.
0-7
Sets LED color to 0-7 as defined in the GLOB
menu. By default, 0=LED Off, 1=Red, 2=Yellow,
3=Green, 4=Cyan, 5=Blue, 6=Magenta, 7=White.
On or Off
Normally the ALERT LED is active only while the
object is receiving a transmission. When Latch is
on, the ALERT LED will remain lit after the
transmission is complete, unless overridden by a
subsequent object that is also using the ALERT
LED.
On, Off or Flash
Controls whether the backlight should be on, off or
flashing while the object is active.
None, Chirp, Hi-Lo, Alert,
Ring, 2-Chirp, Fast Hi-Lo,
DTMF#
Sets the Audible Alarm for the SRVC object. When
an Audible Alarm is selected, the selected alarm will
play anytime the scanner stops for activity on the
SRVC object while scanning.
On or Off
When On, the SRVC object is a member of the
Favorites Scan List.
AM, FM, NFM, AU
Modulation setting for the SRVC search. In most
cases AU will work fine. Use AM to override and
force AM modulation, FM to force FM modulation,
NFM to force narrow FM modulation.
On or Off
When on, applies 20 dB of attenuation to all hits
received on the SRVC search. Useful in areas
where interference from nearby strong signals is
present.
On or Off
Controls whether a Delay is used to wait for reply
traffic after a transmission on the SRVC search.
1-200
Sets the amount of time (in 100 millisecond
intervals) for the wait for reply delay if Delay is On,
e.g., 20=2 seconds.
On or Off
When on, enhances the scanners ability to lock on
to the actual center frequency of a search hit
instead of an adjacent frequency.
Up or Down
Sets search direction used when SRVC object is
active.
Numeric value
Increments each time a transmission is received on
the SWPR object. Global “Hit Counts” must be set
to ON. Press the
Dflt
softkey to reset to 0.
0716
User Manual
Page 110