SWPR Menu Reference
The SWPR menu is used when creating new Spectrum Sweeper
objects, or editing existing Spectrum Sweeper objects. All menus
are shown in the scanners display as a three line window that
can be scrolled up or down to access the various different
parameters. The active parameter is always the middle
parameter and is indicated by a flashing “
:
”. The entire SWPR
menu is shown below:
SWPR
Parameter
Options
Description
Scan Lists
Type
Sub-bands
Tag
L/Out
LED Mode
On or Off for Scan Lists
1-20
Sets membership in Scan Lists. Use
keys to
scroll through Scan Lists. Use
SEL
key to toggle
Scan List membership. A “
*
” next to the Scan List
number indicates that the object is mapped to that
Scan List.
All Bands or Pub Safety
Use
to select All Bands or Public Safety. All
Bands covers the entire frequency range of the
scanner. Public Safety covers frequency ranges
commonly used for public safety communications.
, SEL
Sub bands are available when using SWPR in All
Bands or Public Safety mode. In All Bands, the
sub bands are defined as follows:
0: 25-54 MHz
1: 108-137 MHz
2: 137-174 MHz
3: 216-300 MHz
4: 300-406 MHz
5: 406-470 MHz
6: 470-512 MHz
7: 764-806 MHz
8: 806-869 MHz
9: 896-1300 MHz
In Public Safety, the sub bands are defined as
follows:
0: 33.4-46.5 MHz
1: 151-170 MHz
2: 453-467 MHz
3: 764-806 MHz
4: 851-869 MHz
Alpha-numeric text
The alphanumeric display name for the SWPR
object. Use the standard text entry method or
QTXT to name the object.
On or Off
Permanent lockout for the SWPR search. Also
accessed by pressing
FUNC L/OUT
while the
scanner is stopped on the SWPR object.
Solid or Flash
Controls whether the ALERT LED flashes or
remains on solid when the ALERT LED is used.
0716
User Manual
Page 111