35
KMV-3901/KMV-3911
Installation & Service Manual
Enabling the Densité Controller’s Restore-Point Settings
The Densité CPU-ETH2 controller can keep a restore point for some or all cards in the
Densité frame. The controller’s configuration includes a
default action
that determines what
happens when a card is inserted or restarted. If the default action is set to
update card
settings
then, if a restore point for the same model of Densité card is found on the controller
card, the controller will automatically apply all parameters from the restore point to the
Densité card. This prevents you from changing the card’s network settings. To do so, you
would need to momentarily set the default action to
keep card settings
.
To verify the restore-point settings, and adjust the default action if needed
1 On the Densité frame’s local control panel, press the CONTROLLER button. See
the Densité Frame Control Panel
2 Press the [–] button repeatedly until RESTORE POINTS appears on the display, and then
press the SEL button.
3 Press the [–] button repeatedly until DEFAULT ACTION appears on the display, and then
press the SEL button.
• If the control panel’s display shows KEEP SETTINGS, then the controller
configuration will not prevent you from changing your KMV-3901/3911 card’s IP
address.
• If the control panel’s display shows UPDATE SETTINGS, navigate to KEEP SETTINGS
by pressing the [+] button, and then press the SEL button to apply your change.
4 Press the CONTROLLER button to exit the controller’s menu.
Network Considerations
This multiviewer generates a low to moderate amount of client-to-server data traffic, and
therefore has a minimal bandwidth impact on a network.
TCP/UDP Port Usage
The various KMV-3901/3911 communication protocols require access to specific ports. In
networks where a firewall is present between device A and device B, the ports used to
communicate
from
device A
to
device B must be open on the incoming (external) side of
the firewall.
From client to multiviewer
The following ports must be open on the Client (i.e., the workstation running XEdit):
Note:
All necessary ports are open by default on the multiviewer. There is
no mechanism provided for changing the default settings.
Port
Used for
Transport Notes
443
HTTPS
TCP
Used by XAdmin for secure access
7
HTTP
TCP
Used by XEdit for ping probing
80
TCP
Used by XEdit and XAdmin
Summary of Contents for KMV-3901
Page 20: ...20 Installation Mechanical Installation of KMV 3901 3911 Cards in the Densité Frame ...
Page 26: ...26 Multiviewer Cabling Commissioning the Multiviewer ...
Page 42: ...42 System Configuration XEdit Installation XEdit Installation ...
Page 102: ...102 System Configuration Enabling Options ...
Page 137: ...137 KMV 3901 KMV 3911 Installation Service Manual ...