Port
: This field is not used during a LAN-only installation.
Address
: Panel address from 01 to 64 (01 to 16 for Serial). This address must
be unique for panels that are associated with the same Control module. L-S
panels are normally shipped with a panel address of “01.” This number is
referred to as the “Device Number” on the IP configuration page and “ID”
within the L-S menu system.
Input Set
: The name of the CP Input set that will be assigned to this panel.
The usual practice is to have one CP Input Set, containing the names of all
Sources, applied to all panels. However, special CP Input Sets could be
created which list only selected Sources; such a set could be used to prevent
certain panels from selecting specific Sources.
•
For a Button-per-Source panel (L32, L64, S25, S50, and S100) the CP
Input set can be used to assign Sources to specific Source buttons where
the first Source in the table corresponds to the first button on the panel,
etc.
In Panel
: This column is not used for L-S panels.
Output Set
: Output Set name. Creation of CP Output Sets is described in both
the
Jupiter CM-4000 Installation and Operating manual
and the
Jupiter CM-
4400 Installation and Operating manual
.
•
For an S25 or S50 panel, with entry of a single Destination name, the
panel will operate as a one-Destination panel. The eight-button cluster
on the right-hand side of the panel will be used to control the first eight
levels of the router.
•
For an S25 or S50 panel, with selection of an Output Set with two, three,
or four Destinations defined, the panel will operate as a two-, three-, or
four-Destination panel respectively. With respect to the eight-button
cluster on the right-hand side of the panel, the top row of four buttons
will be used to select the Destination; the bottom row of four buttons
will be used to control the first four levels of the router.
•
For an S25 or S50 panel, with selection of an Output Set with five, six,
seven, or eight Destinations defined, the panel will operate as a five-,
six-, seven-, or eight-Destination panel respectively. The eight-button
cluster on the right-hand side of the panel will be used to select the Des-
tination.
•
For all other L-S series panels, if an actual CP Output Set is selected,
then the control panel will be able to control all the Destinations listed
in that Set; depending on the contents of the set, this would allow for
full-matrix or multi-bus control. Alternatively, this field can be used to
enter the name of a single switcher Destination to be controlled; the
Source of the Destination name is the Switcher Output table.
Out Panel
: This column is not used for L-S panels.
Level Set
: Select the CP Level Set name.
Summary of Contents for JUPITER -
Page 12: ...12 JUPITER L S and LCD Series Control Panel Instruction Manual Contents ...
Page 14: ...14 JUPITER L S and LCD Series Control Panel Instruction Manual Preface ...
Page 30: ...30 JUPITER L S and LCD Series Control Panel Instruction Manual Regulatory Notices ...
Page 156: ...156 JUPITER L S and LCD Series Control Panel Instruction Manual Section 7 LCD Introduction ...
Page 164: ...164 JUPITER L S and LCD Series Control Panel Instruction Manual Section 10 LCD Configuration ...
Page 202: ...202 JUPITER L S and LCD Series Control Panel Instruction Manual Appendix C GPI O ...
Page 210: ...210 JUPITER L S and LCD Series Control Panel Instruction Manual Glossary ...
Page 220: ...220 JUPITER L S and LCD Series Control Panel Instruction Manual Index ...