13

4 - Ironing speed down
5 - VMS: "Machine working" lamp
6 - Machine START button
7 - Machine STOP button
8 - VST : "Machine live" lamp
9 - Preset temperature up
10 -Preset temperature down
11- Preset temperature reading

4.3 MACHINE USE
START UP
To start the machine, press the START but-
ton:

START

- the display will light up and show the
current temperature and preset speed (cf.
chapter “Control of roller rotation”).
- the VMS lamp will light up (VST always
on when the machine is powered)
- the fan will start working
- the roller will start revolving
- after 15 seconds, the heating is authorized

SHUTDOWN PROCEDURE
To stop the machine, press the STOP button.

STOP

The shutdown procedure depends on the
current temperature.
 - if the temperature is 

  automatic shut-

down temperature TA (by default 80

°

C), the

machine switches off.
- if the temperature is > temperature TA,
only the heating is switched off. When the
temperature drops below the temperature
TA, the whole machine will switch off.
Meantime, the temperature reading and the
VMS lamp will blink.
TA can be programmed by the manufacturer
or at the time of installation (see “Parameter
Programming “).

4.4 CONTROL OF ROLLER ROTA-
TION
The roller motor is controlled by a speed
regulator.
You may select 7 different factory preset
speeds, while speed 0 is used for the SMART
SYSTEM option  speed adjustment accord-
ing to humidity).
The speed may be adjusted by the user when
the machine is ON by pressing the two arrow
keys « up » and « down ». The result is shown
on the speed display.

  

(Es.)

The last selected value will be recalled even
after a power break.
When the selected speed is not 0 upon start-
ing the machine, the roller will rotate at
speed 1 while the detected temperature re-
mains below the operating temperature TF
(130

°

C by default); once this temperature is

reached, the programmed speed will be acti-
vated.
If the temperature drops below TF during
operation, the roller speed will be read-
justed.
When the selected speed is 0, the belt will
rotate at speed 0 (i.e. the speed required by
the SMART SYSTEM), regardless of the
temperature.

4.5 HEATING
ELECTRICAL HEATING
Depending on the model, the electrical heat-
ing consists in modifying the current through
one or two groups of heaters, controlled by
the heating switches.
The choice between 1 or 2 heating units is
made by setting a parameter (see “Program-
ming parameters”).

HEATING BY A SINGLE HEATING
UNIT
When the machine is configured to work
with a single heating unit, a special control
function is activated (closing and opening
the heating relay switch around the set point)
in order to achieve and maintain the preset
temperature correctly and to avoid the ther-
mal overshoot associated with this kind of
heating.
It is therefore normal to hear the heating
relay switch switching frequently when you
select this functionality.
To show that the heating is on and working,
the decimal point of the temperature reading
lights up.

HEATING BY TWO HEATING UNITS
When the machine configured to work with
two heating units, the temperature regula-
tion switches the first unit just as if it were
the only controlled unit. The second is oper-
ated continuously when the temperature gets
below the required setting, and switches off
when the setting is attained. The second unit
also goes on when below a preset hysteresis
(see “Programming parameters”).
To show that the heating is activated, the
decimal point of the temperature reading lights
up continuously when both heating units are
on, and blinks when only one unit is.

GAS HEATING
On gas-heated appliances, a special elec-
tronic device controls the ignition and work-
ing of the heater. The microprocessor con-
trols the gas igniter directly when the tem-
perature is lower than the preset temperature.
As for resetting gas devices, reference is
made to the alarm section.
To show that the heating is activated, the
decimal point of the temperature indication
lights up.

The Alarm section also explains what to do
in the event that there is no flame.

INDIRECT STEAM HEATING
When the heating is done using the indirect
steam method, the machine will not perform
any temperature regulation (and the tem-
perature will be directly proportional to the
steam pressure fed to the machine).
The microprocessor simply reads the tem-
perature of the roller but will not affect the
heating itself.

PROGRAMMING THE OPERATING
TEMPERATURE
The operating temperature may be set when
the machine is on, using the following pro-
cedure:
Press the SET button.
The value set last will blink on the display.

SET

Use the + and – keys to change this value.
Hold the key down to change the number
rapidly.

  

3 seconds after releasing the + or – key, the
displayed value is stored; then the display
again will read the currently detected tem-
perature.
Programmable range: 0...Tmax 

°

C

(32...Tmax 

°

F)

Resolution: 1

°

C

The maximum value that the user may set
(Tmax) is established by the manufacturer
or at the time of installation by a special
procedure. See “Programming parameters”.
When the selected heating method is electri-

Summary of Contents for C 140/33

Page 1: ... EMPLOI INSTALLATIONS UND GEBRAUCHSANWEISUNG INSTRUCCIONES PARA LA INSTALACIÓN Y PARA EL USO CALANDRA A RULLO GAS ELETTRICO DRYING IRONERS GAS ELECTRIC CALANDRES GAZ ÉLECTRIQUE TROCKENMASCHINE GAS BZW ELEKTROBETRIEB CALANDRIAS GAS ELECTRICO C 140 33 C 160 33 C 200 33 VIA MASIERE 211 C 32037 SOSPIROLO BL ITALY ELECTRONIC ...

Page 2: ......

Page 3: ...vent of a long layoff period 12 4 USEOFMICROPROCESSOR EASYCON TROL 4 1 General 12 4 2 User interface 13 4 3 Machine use 13 4 4 Control of roller rotation 13 4 5 Heating 13 4 6 Alarm messages 14 5 PERIODIC MAINTENANCE 5 1 Daily 14 5 3 Weekly 15 5 3 Every 200 hours 14 5 4 Every 2000 hours 15 6 INSTRUCTIONS FOR MAINTENANCE 6 1 Changing introduction strips 15 6 2 Changing ironing strips 15 6 3 Changin...

Page 4: ...ina utilizzabile su tutta la larghezza della macchina Un secondo dispositivo d arresto d emergenza è posto nei pressi del quadro di comando 1 4 2 SICUREZZE RELATIVE AL RISCALDAMENTO Iltermostatodiregolazionepostosulquadro di comando garantisce la regolazione della temperatura del rullo stirante entro i limiti di surriscaldamento delle fasce interruzione del riscaldamento quando si superano i 185 C...

Page 5: ...llegamento gas per le macchine che utilizzano questo tipo di riscaldamento collegare l apparecchio alla tubazione gas esistente con l accorgimento di installare a monte della macchina un rubinetto d intercettazione che permetta di isolare l apparecchio dal resto dell impianto L installazione va eseguita in conformità alle norme e ai regolamenti applicabili nel paese in questione La tubazione d ali...

Page 6: ...re ma non deve mai superare i 180 C continui Un termostato di sicurezza regolato in fabbrica e posto all interno della macchina halafunzionedisopperireadognieventuale guasto del sistema di regolazione Per iniziare il lavoro è indispensabile attendere che il rullo della macchina sia ad unatemperaturaprossimaaquelladesiderata laspiadiriscaldamentosispegnenonappena il rullo arriva in temperatura Quan...

Page 7: ...rica All avviamentodellamacchina selavelocità stabilita è diversa da 0 il rullo girerà alla velocità 1 fino a quando la temperatura rilevata non sia inferiore alla temperatura di funzionamento TF per default 130 C una volta raggiunto questo valore si attiverà la velocità programmata Se durante l utilizzo della macchina la temperatura scende ancora al di sotto di TF la velocità viene modificata Sel...

Page 8: ...urante i primi 10 secondi di funzionamento della ventola al fine di consentire la normalizzazione del flusso d aria L allarme rientra automaticamente nel momento in cui il pressostato ritorna in posizioneoallospegnimentodellamacchina PROFILO SALVADITA AL2 In caso di intervento del dispositivo salvadita profilo salvadita il segnale acustico si attiva per1minutoeapparelascritta AL2 adisplay La macch...

Page 9: ...bero di deteriorarsi rapidamente Verificare l appoggio del rullo pressore il qualenondevecomprimereeccessivamente madeveunicamentedistenderelabiancheria Ciò serve a garantire una buona qualità di stiratura Attenzione Tendere in misura identica ognuna delle 2 molle di tensione Per controllarelasimmetriadiquestaregolazione bisognacontareilnumerodiforisulsistema ditensione Illoronumerodeveessereident...

Page 10: ...e of the ironing belt remains below the overheat inglimitsofthestrips theheatingisswitched offwhenthemaximumtemperatureof185 c is exceeded Asafetythermostat 190 C putstheheating off when the regulation thermostat fails 1 4 3 GAS HEATING SYSTEM SAFETY When a gas system fault occurs the gas supply to the machine is shut off and the display reads alarm AL6 After the beep has ended reset the gas sys t...

Page 11: ...d regulations applicable in the relevant country The gas supply piping must have dimen sions sufficient to minimise pressure loss its diameter must be determined following the route of the piping length number of bends and the machine power Check that the settings of the device corre spond to the type and the pressure of the gas available at the installation site To check the pressure of the gas f...

Page 12: ...ndry it is necessary to alternately use the whole iron ing length this will provide uniform results and guarantee a longer life of the ironing strips that would otherwise be exposed to rapid deterioration For perfectly dry and ironed laundry the working speed must be adjusted following the nature and humidity of the items that are to be ironed Important When the work is done press STOP the machine...

Page 13: ...o work with a single heating unit a special control function is activated closing and opening theheatingrelayswitcharoundthesetpoint in order to achieve and maintain the preset temperature correctly and to avoid the ther mal overshoot associated with this kind of heating It is therefore normal to hear the heating relay switch switching frequently when you select this functionality To show that the...

Page 14: ...y be due to roller motoroverload machinejammingorblocked roller NO FLAME AL6 This alarm is only activated when the card is configured to work with gas heating When the burner is on or being ignited and the no flame condition occurs the buzzer is activated for 1 minute and the display reads AL6 The command for ignition remains active and the machine remains on To try to re ignite the burner press t...

Page 15: ...move the adjustable pinion along its rail 5 4 EVERY 2000 HOURS On gas heated machines check the gas ex haust conduits and have the chimney swept if needed On electrically heated machines check that your vapour exhaust tube is not partially blocked and clean it if needed 6 INSTRUCTIONS FOR MAINTE NANCE Before any jobs the machine must always be stopped the roller cold and the circuit breaker with g...

Page 16: ...bleau de contrôle 1 4 2 SÉCURITÉ LIÉE AU CHAUFFAGE Le thermostat de régulation situé sur le tab leau de commande assure la régulation de la température du cylindre de repassage en dessousdeslimitesdesurchauffedesbandes coupure de la chauffe à 185 maximum Un thermostat de sécurité à 190 coupe le chauffage en cas de défaillance du thermo stat de régulation 1 4 3 SÉCURITÉ LIÉE AU SYSTÈME DE CHAUFFAGE...

Page 17: ...ité L installation devra se faire dans le respect des normes et réglementations en vigueur Un disjoncteur différentiel non fourni en rapport avec la puissance de la machine doit être prévu à proximité de celle ci Raccordement gaz pour les machines utilisant ce mode de chauffage raccorder l appareil à la canalisation de gaz existante en interposant une vanne de barrage permettant d isoler l apparei...

Page 18: ...textile à repasser mais ne doit jamais dépasser 180 C en continu Un thermostat de sécurité pré réglé situé à l intérieur de la machine a pour fonction de palier à toute défaillance éventuelle du système de régulation Pour commencer le travail il est indispens abled attendrequelecylindredelamachine soit à une température proche de la température souhaitée le voyant chauffage s éteint lorsque la tem...

Page 19: ...Àlamiseenroutedelamachine silavitesse établieestdifférentede0 lecylindretournera àlavitesse1tantquelatempératuredétectée sera inférieure à la température de fonctionnement TF 130 C par défaut une fois atteint cette valeur la vitesse programmée est activée Si pendant l utilisation de la machine la température descend encore sous TF la vitesse sera modifiée Silavitessechoisieest0 lecylindretournera ...

Page 20: ...er votre système d évacuation si lorsque vous débranchez le tuyau de sortie des buées au dessus de la machine l alarme disparaît il y adeforteschancespourquevotretuyauterie soit sous dimensionnée ou obstruée L alarme n est pas vérifiée pendant les 10 premières secondes de fonctionnement du ventilateur pour permettre la normalisation du flux d aire L alarme est annulée automatiquement quand le cont...

Page 21: ...s régler les tendeurs de manière à ce que les bandesderepassageaientuncontactsuffisant aveclecylindrepourl entraînercorrectement sans à coup même avec du linge Attention effectuer une tension identique surchacundes2tendeurs Pourcontrôler la symétrie de ce réglage vérifier la cote entre l équerre et l écrou de tension des bandes Cette cote doit être identique de chaque coté de la machine Veillez à ...

Page 22: ...alets neufs Bloquer les galets en position sur la barre voir cote à respecter Bloquer la barre sur les paliers droits Remonter les panneaux 6 4 REMPLACEMENT DES GALETS LATÉRAUX Retirer les panneaux de coté Retirer la vis de maintien du galet Retirer l entretoise du galet usé Remettre un galet neuf sur l entretoise Remettre le nouveau galet en position ...

Page 23: ...SCHEMI DIAGRAMS SCHEMAS ...

Page 24: ...VISTA LATERALE SIDE VIEW VUE ...

Page 25: ...SCHEMA D INSTALLO C200 LAYOUT DRAWING C200 PLAN D IMPLANTATION C200 ...

Page 26: ...SCHEMA D INSTALLO C160 LAYOUT DRAWING C160 PLAN D IMPLANTATION C160 ...

Page 27: ...SCHEMA D INSTALLO C140 LAYOUT DRAWING C140 PLAN D IMPLANTATION C140 ...

Page 28: ...CRUSCOTTO CONTROL PANEL TABLEAU DE COMMANDE SCARICO FUMI SX LEFT EXHAUST EVACUATION GAUCHE SCARICO FUMI RX RIGHT EXHAUST EVACUATION DROITE PROFILO SALVADITA E INTERRUTTORE D EMERGENZA OPERATOR SAFETY AND EMERGENCY SWTCH TABLETTE DE SECURITE ...

Page 29: ...PULIZIA PORTASONDA SENSOR CLEANING NETTOYAGE PALPEUR ...

Page 30: ...INSIEME PORTASONDA RAMPA DI DISTACCO SENSOR SEPARATION BLADES EMSEMBLE PALPEUR DECOLLEUR ...

Page 31: ......

Page 32: ...SCHEMA ELETTRICO RISCALDAMENTO ELETTRICO E A VAPORE WIRING DIAGRAM ELECTRIC AND STEAM HEATING SCHÉMA ÉLECTRIQUE CHAUFFAGE ÉLECTRIQUE ET À VAPEUR ...

Page 33: ...SCHEMA ELETTRICO RISCALDAMENTO A GAS WIRING DIAGRAM GAS HEATING SCHÉMA ÉLECTRIQUE CHAUFFAGE À GAS ...

Page 34: ...SCHEMA ELETTRICO WIRING DIAGRAM SCHÉMA ÉLECTRIQUE ...

Page 35: ...S ELECTRICAL HEATING NOMENCLATURE ÉLECTRIQUE CHAUFFAGE ÉLECTRIQUE SOLO PER Ø 32 E 50 ONLY FOR Ø32 AND 50 UNIQUEMENT POUR Ø32 ET 50 V2 SOLO PER C200E C250 320 ELETTRICHE V2 ONLY FOR C200E AND ELECTRICAL C250 320 V2 UNIQUEMENT POUR C200E ET C250 320 ELECTRIQUE ...

Page 36: ...S GAS AND STEAM HEATING NOMENCLATURE ÉLECTRIQUE CHAUFFAGE Á GAZ ET VAPEUR V2 SOLO PER C200 CALANDRE A GAS E C250 320 A VAPORE V2 ONLY FOR C200 GAS HEATED DRYERS AND STEAM HEATED C250 320 V2 UNIQUEMENT POUR C200 APPAREILS AVEC CHAUFFAGE A GAZ ET C250 320 A VAPEUR ...

Page 37: ...SCHILD PLACA DE CARACTERÍSTICAS RIVENDITORE DISTRIBUTOR REVENDEUR VERTRIEB VENDEDOR ASSISTENZA TECNICA AFTER SALES SERVICE SERVICE APRES VENTE KUNDENDIENST SERVICIO DE ASISTENCIA TÉCNICA MODELLO MODEL NR MATR SERIAL NR ALIM EL EL POWER POTENZA TOT TOTAL INPUT PRESSIONE VAPORE STEAM PRESSURE ATTENZIONE E OBBLIGATORIO IL COLLEGAMENTO A TERRA CAUTION THE APPLIANCE MUST BE CONNECTED TO EARTH ...

Reviews: