Section 5 - Lubrication & Maintenance
5-26
80804002
Air Filter Restriction Indicator Check
1. Perform shutdown procedure on page 3-14 or page 3-33.
2. Locate air cleaner
(1)
and check restriction indicator
(2)
. If red band is visible,
filter(s) must be replaced.
3. Remove dust from vacuator valve
(3)
by squeezing bottom of valve to allow
loose particles to fall out.
4. Locate air inlet hood
(9)
loosen clamp
(8)
and remove hood.
5. Remove dust from hood.
6. Replace air inlet hood.
Note:
Only remove air cleaner
(4)
cover to service the elements as restriction
indicator indicates. Excessive access to check an element can lead to premature
element failure.
10
OAC1030
OW1010
4
3
6
7
5
9
8
2
1
OAC1080
Summary of Contents for XL3100IV
Page 6: ...Read This First d 80804002 NOTES...
Page 24: ...Section 1 General Safety Practices 1 14 80804002 NOTES...
Page 33: ...Section 2 Pre Operation and Controls 2 9 80804002 NOTES...
Page 53: ...Section 2 Pre Operation and Controls 2 29 80804002 NOTES...
Page 61: ...Section 2 Pre Operation and Controls 2 37 80804002 NOTES...
Page 79: ...Section 3 Operation 3 9 80804002 NOTES...
Page 108: ...Section 3 Operation 3 38 80804002 This Page Intentionally Left Blank...
Page 152: ...Section 5 Lubrication Maintenance 5 38 80804002 NOTES...
Page 164: ...Section 7 Specifications 7 10 80804002 This Page Intentionally Left Blank...