Custom
Custom
Custom Valve
Valve
Valve Mapping
Mapping
Mapping
For the PD3K+, every color change solenoid may be
assigned to any unique, valid control module location.
Pump
Pump
Pump Screen
Screen
Screen --- Advanced
Advanced
Advanced Configuration
Configuration
Configuration
Figure 64 Pump Screen, Advanced Configuration
Inlet
Inlet
Inlet Color
Color
Color Change
Change
Change
Select Multiple if each individual material has its own
valve on the inlet color stack for a particular pump.
Select Single if there is more than one material using
a single valve on the inlet color stack (i.e., a piggable
system). This option is only available for pumps that
have more than one color change material.
NOTE:
NOTE:
NOTE: For systems that select Single, it is expected
the user knows when a particular material is plumbed
and filled to the inlet stack before performing a color
change. The PD3K+ system does not know what
material is connected up stream of the inlet valve
stack.
Pump
Pump
Pump Air
Air
Air Purge
Purge
Purge
Select Enable to add an air purge valve to the pump
inlet stack to allow for an air/solvent chop flush of the
pump out the dump valve. Select Disable if no air
purge valve will be used for the pump. See Pump
Air/Solvent Chop on
, for
further detail.
Outlet
Outlet
Outlet Color
Color
Color Change
Change
Change
Select Multiple if each individual material has its own
valve on the outlet color stack for a particular pump.
Select Single if there is more than one material using
a single hose connected to the outlet color stack.
This option is only available for pumps that have
more than one color change material.
NOTE:
NOTE:
NOTE: If Single is selected, the hose connected
to the outlet stack will need to be purged before
completing a color change.
Remote
Remote
Remote Color
Color
Color Change
Change
Change
Select Multiple if each individual material has its own
valve on the remote color stack for a particular pump.
Select Single if there is more than one material using
a single hose connected to the remote color stack.
Select Disable if there are no remote color change
valves (only solvent and air purge) for the pump.
Single is only available for pumps that have more
than one color change material.
NOTE:
NOTE:
NOTE: Unless Disabled is selected, this must match
the selection for Outlet Color Change.
NOTE:
NOTE:
NOTE: If Single is selected, the hose connected
between the outlet stack and remote stack will need
to be purged before completing a color change.
Clear
Clear
Clear Valve
Valve
Valve Map
Map
Map
Check this box to clear all valve assignments. The
user will be prompted to confirm the choice. This will
erase any valve assignments permanently, including
any that were automatically set based on the static
mapping.
84