Operation Using a Programmable Logic Controller (PLC)
Read
Read
Read Recipe
Recipe
Recipe
The Read Recipe command returns component selections for a desired recipe number. The number of the recipe
to be read is the only argument.
Example: Read Recipe 5 data as it is currently configured with Component A = 3, Component B = 2 (32), Component
C = 1 (39).
DCS
DCS
DCS Register
Register
Register
Parameter
Parameter
Parameter Description
Description
Description
Data
Data
Data
Type
Type
Type
Units
Units
Units
Value
Value
Value
Range
Range
Range
DCS
Command
Read Recipe
uint32
NONE
11
0 - 19
Argument 0
Recipe #
uint32
NONE
5
0 - 40
Acknowledge
Command Acknowledged
uint32
NONE
2 = ACK
0 - 4
Return 0
Recipe #
uint32
NONE
5
0 - 40
Return 1
Component A
uint32
NONE
3
0 - 30, 61
Return 2
Component B
uint32
NONE
32
0, 31 - 38, 61
Return 3
Component C
uint32
NONE
39
0, 39 - 46, 61
Return 4
Component D
uint32
NONE
N/A
0, 47 - 54, 61
Return 5
Recipe Gun Assignment
uint32
NONE
1
1 - 3
Read
Read
Read Fluid
Fluid
Fluid Control
Control
Control Mode
Mode
Mode
The Read Fluid Control Mode command is used to read the current Fluid Control mode of the system is currently
operating under. No arguments are required.
Example: Read Fluid Control as currently set to
Pressure mode.
DCS
DCS
DCS Register
Register
Register
Parameter
Parameter
Parameter Description
Description
Description
Data
Data
Data
Type
Type
Type
Units
Units
Units
Value
Value
Value
Range
Range
Range
DCS
Command
Read Fluid Control Mode
uint32
NONE
12
0 - 19
Acknowledge
Command Acknowledged
uint32
NONE
2 = ACK
0 - 4
0 = Flow
Return 0
Fluid Control Mode
uint32
NONE
1 = Pressure
1 = Pressure
3A6287E
51