![Gotting HG G-98810-C Technical Description Download Page 48](http://html1.mh-extra.com/html/gotting/hg-g-98810-c/hg-g-98810-c_technical-description_2247545048.webp)
Technical Data
English, Revision 05, Date: 28.11.2016
48
8
Technical Data
Antenna HG G-98810-C
Casing
Weight
approx. 10 kg
Effective antenna area
500 x 175 mm (function range positioning)
Power supply antenna
24 V -20% +50%, max. 1,1 A @ 24 V
Operating temperature
-20 to +50
o
C, heating period 5 min
Mechanical stability
5 g 11 ms / 2 g 10 to 55 Hz
Metal and interference
free area
-
no closed loop within 300 mm around the antenna, especially around
the cover
-
no metal surfaces nearer than 50 mm
-
Current-carrying wires have to be far enough away from the antenna
(minimum 150 mm) so that their power and frequencies does not influ-
ence the antenna too much, its sum voltage in idle mode has to be
below 50 and during driving below 100 (guideline: For very high or very
small reading distances those values may be higher/lower. The sum
voltage without a transponder in the reading area should always be
smaller than half the sum voltage that is generated by a transponder
within the reading area).
The only exception to this rule is the connection cable of the antenna
itself.
Protection class
IP 65
Max. pass-over speed
3 m/s
Reading distance (dis-
tance transponder -
underside reading
antenna)
-
30 to 90 mm (with HW DEV00095/HW DEV00098)
-
50 to 150 mm (with HG G-71325XA)
Nominal reading dis-
tance
-
60 mm (with HW DEV00095/HW DEV00098)
-
100 mm (with HG G-71325XA)
Width of the active
Antenna reading area
±250 mm
Static positioning accu-
racy
±5 mm @ nominal reading height; also refer to section F on page 65)
Connection
3 M12 connectors
Signal processing time
8 ms
output RS 232 / RS 422
The connection speed is 19200 or 38400 Bd. The telegram content may be
configured. 3964R or “transparent“ protocol selectable
Output positioning pulse
20 mA current source, isolated
CAN interface
Isolated
Terminating resistor (Terminator) not integrated
Full CAN
Basic CAN
According to ISO/DIS 11898 Identifier, Data rate, Basic/Extended CAN;
configurable via serial interface
CANopen
®
CANopen, Device Profil DS 401
Node ID and transmission rate configurable via serial interface or SDOs
Table 23