Components and Operation
English, Revision 05, Date: 28.11.2016
23
*)
XOR operation of all bytes including the start character. Depend-
ing on the parameters used.
**)
No ASCII-coded values
4.2.3.2
System Monitor
The system may be configured via menus in monitor mode. Refer to section 5.2 „Sys-
tem Monitor“ on page 29.
4.2.3.3
CAN
4.2.3.3.1
Description
The internal CAN module is based on the CAN specifications V2.0 part B. Standard or
Extended frames are transmitted (configurable). It is also possible to configure the bit
timing as well as the identifier within the system monitor (refer to section 5.2 on page
Different CAN message objects can be output. In addition it is configurable whether
telegrams are to be output permanently at the set update rate or only as long as a Tran-
sponder is within range. Remote operation is also possible. Objects are activated with-
in the CAN menu, through the input of an address unequal 0 (refer to section 5.2.2.5
Message Object 3 is used for the analysis of the system behavior.
19
3964R
HEX
53
16
50
16
0 ... 3E8
16
Set postioning level
(0 <= level < 1024)
ASCII
SP
**)
trans-
parent
HEX
3D
16
53
16
50
16
0 ... 3E8
16
***)
ASCII
=
SP
**)
**)
**) No ASCII-coded values
***) Check sum depending on the parameters used. Examples:
-
Level should be set to 1000 (3E8
16
)
The transparent telegram is: 3D
16
53
16
50
16
03
16
E8
16
D5
16
-
Level should be set to 300 (12C
16
)
The transparent telegram is: 3D
16
53
16
50
16
01
16
2C
16
13
16
No.
Procedure
Start
Command
Bytes
Parameter
Bytes
Check
Sum *)
Description
Table 8
List of the system commands (part 4 of 4)