![Gotting HG G-98810-C Technical Description Download Page 33](http://html1.mh-extra.com/html/gotting/hg-g-98810-c/hg-g-98810-c_technical-description_2247545033.webp)
Software
English, Revision 05, Date: 28.11.2016
33
Further menus are activated via input of the (characters in brackets). Before altered
values are transferred into the permanent memory, they have to saved as described
in section 5.2.2.10 on page 42. This prevents unwanted alterations of values. With
the values are saved after alteration and input of the password.
Input of
will exit each menu.
The following sections describe the submenus
-
(
)erial Output (section 5.2.2.2 on page 34)
-
(
)ime & code (section 5.2.2.3 on page 36)
-
(
)requency & Antenna tuning (section 5.2.2.4 on page 38)
-
C(
)N Parameters (section 5.2.2.5 on page 39)
-
CA(
)open Parameters (section 5.2.2.6 on page 40)
-
isplay Systemstatus (5.2.2.7 on page 41)
-
Cs(
) (section 5.2.2.8 on page 41)
-
display (
)Histogram (section 5.2.2.9 on page 42)
-
(
)oad values to EEProm (section 5.2.2.10 on page 42)
-
(
)pdate Firmware (section 5.2.2.11 on page 43)
-
(
) Import / (
) Export User Parameter (section 5.2.2.12 on page 43) and
-
P(
)int Parameters (section 5.2.2.13 on page 43).
U [mV]
Supply voltage of the processor board measured with an accuracy of 100 mV. This volt-
age is, due to various safety measures, always a little lower than the connected overall
supply voltage
I [mA]
Current consumption of the positioning unit measured with an accuracy of 10 mA
T [Grd.C]
Average temperature measured in steps of 5
o
C
E
Hexa decimal system status. The description of the individual bits is included in Table 7
on page 19
Noise
Output of a counter:
-
Whenever the sum voltage S exceeds the
Threshold for Decoding
the counter is
increase every 8 ms until it reaches the value of
Level to Noise Error
.
-
Whenever S falls under this threshold, the counter counts backwards towards 0. When
a code is decoded, the counter is immediately set to 0.
This mechanism checks whether a Transponder or a foreign signal is received. Every
time this counter exceeds an adjustable value (refer to section 5.2.2.3 „(T)ime & Code“ on
page 36), the system status bit RX_NOISE is set.
Description of the system variables
Table 21
Description of system variables (monitor program) (part 2 of 2)