What is a parallel move of the heating curve?
At start-up, the heating curve is adjusted according to the heating system (Floor heating
system, Radiators, Fan coils) and desired room temperature.
The setting can be changed from the Main screen, but only the complete move of the heating
curve and not each reference point separately. The heating curve can be raised or lowered
for 3 °C (-3 to +3).
By raising the heating curve for 2-
3 °C would mean an increase of the room temperature for
approx. 1 °C.
The graph below shows a parallel move of the heating curve
– lowering of the heating curve
for 2°C
7.1.1 SETTING THE PARALLEL MOVE OF THE HEATING CURVE
– HEATING
CIRCUIT 1
Parallel move of the
heating curve for -
2°C (Parallel move
set to - 2)
Heating Curve
–
normal setting
(Parallel move set to
0)
Ambient temperature (°C)