7.1.2 SETTING THE PARALLEL MOVE OF THE HEATING CURVE
– HEATING
CURVE 2
PARALLEL MOVE OF THE HEATING CURVE 2 IS AVAILABLE ONLY WHEN USING TWO
HEATING CIRCUITS!
First the window for parallel move of the first heating circuit appears. To access the setting of
the parallel move for the second heating circuit press
. Second page appears with the
setting for the second heating circuit.
With buttons ˝
+
˝ or ˝
–
˝ the heating curve can be changed for the desired value. Confirm the
setting with button ˝
OK
˝.
7.2 SETTING
THE
DHW
TEMPERATURE
By pressing on the DHW temperature, an additional window appears.
With buttons ˝
+
˝ or ˝
–
˝ the DHW set temperature can be changed for the desired value.
Confirm the setting with button ˝
OK
˝.
Domestic hot water settings depend on the user’s habits.
The recommended setting for domestic hot water is betwe
en 47 °C and 50 °C.
Traditional systems (boilers) use smaller domestic water storage tanks, so the temperature
must be significantly higher than in a heat pump system, which causes higher costs of
domestic hot water preparation!
In principle, a heat pump system is planned to store 50 litres of water per person. This
means that a family of four needs a minimum of 200 litres of hot water per day.
Note:
Mixing of cold and warm water in a mixing tap differs according to the systems of how
domestic water is heated.
If the traditional domestic water heating system is used, less hot water is mixed with cold
than in a heat pump system.
By pressing on the room temperature
display, an additional window
appears.
.
OK
Cancel
System 1 Heating Curve Parallel Move 2: 0°C
OK
Cancel
Desired temperature: 47°C