45
EN
11 C
LEANING THE MAGNETIC
/
D
IRT FILTER
C
ALEFFI
The Filter should be cleaned at the beginning and of the heating season.
Note:
First heating season, it is recommended to clean the Filter first time after 1 month working of
the heat pump and until the end of the firs heating season every 2 months. If there is still
much dirt collecting in the filter, repeat this procedure until the system is free of excessive
dirt.
1. Turn OFF the heat pump
with the ON/OFF button
and wait for min 5 minute
before proceeding to the
next step.
2. Close the hand valves.
3. Remove the Magnet and
wait for 5 minutes before
proceeding to the next
step.
4. Drain the dirty water.
5. Remove the Dirt Filter.
6. Remove the strainer from
the holder.
7. Clean the strainer with
warm water under a tap.
8. Reassemble the filter and
close the draining valve.
9. Open the hand valve on
the low side.
10. Purge the air from the
Filter.
11. Retreave the Magnet.
12. Open the uper hand valve.
13. Start the Heat Pump with the ON/OFF button.
Summary of Contents for Aerogor POWER EVI Inverter 15 A